ZEN-10C2AR-A-V2 Omron, ZEN-10C2AR-A-V2 Datasheet - Page 38

100/240 VAC 6 IN, 4 OUT

ZEN-10C2AR-A-V2

Manufacturer Part Number
ZEN-10C2AR-A-V2
Description
100/240 VAC 6 IN, 4 OUT
Manufacturer
Omron
Series
ZEN V2r
Type
Expandabler

Specifications of ZEN-10C2AR-A-V2

Voltage - Supply
100 ~ 240VAC
Number Of I /o
6 Input, 4 Output
Display Type
LED
Output Type
Relay
Voltage Rating
100 V to 240 V
Input Type
AC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Kit Contents
-
Analog Inputs
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
Z2680
ZEN10C2ARAV2
22
Reading and Writing Timer Set Values
SECTION 2 CompoWay/F Communications Protocol
Writing Timer and Counter Set Values
Example 1:
Example 2:
Example 3:
Example 4:
[STX]000000102C100000000010000270F
[STX]00000010100000000270F
[STX]000000102C100000000010064 270F
Error Occurred
Note: With the Write Variable Area service,
Timer set values (SVs) can be read and written. The rightmost and
leftmost four bytes contain the ON time and OFF time for twin timers
and the rightmost four bytes contain the ON time for other timers.
Writing the SV of Timers Other Than Twin Timers
Command
Reading the SV of Timers Other Than Twin Timers
Command
[STX]000000101C10000000001
Response
Writing the SV of Twin Timers
Command
Writing the SV of Twin Timers
Command
[STX]000000101C10000000001
1002
1101
1003
1100
3003
2203
Response
code
do not occur. If there is sufficient data for the number of elements
in the service request PDU, the error is processed as a
of elements/data mismatch” error.
Command too short
Area type error
Number of elements/
data mismatch
Parameter error
Read-only error
Operation error
Error name
The command is too short.
The variable type is wrong.
The number of data does not
match the number of elements.
• Bit position is not 00.
• The write data is out of the set-
• The bit number is out of range.
Variable type “C0” was written to.
Unit error (Memory error
occurred, or unused command
was sent.)
ON time: 9999 (H'270F)
OFF time: 9999 (H'270F)
ON time: 100 (H'64)
ON time: 9999 (H'270F)
ting range.
command too long” errors
Cause
number

Related parts for ZEN-10C2AR-A-V2