G2A-432A-DC48 Omron, G2A-432A-DC48 Datasheet - Page 4

no-image

G2A-432A-DC48

Manufacturer Part Number
G2A-432A-DC48
Description
RELAY
Manufacturer
Omron
Series
G2Ar
Datasheet

Specifications of G2A-432A-DC48

Relay Type
General Purpose
Circuit
4PDT (4 Form C)
Contact Rating @ Voltage
0.5A @ 24VDC
Coil Type
Standard
Coil Current
22mA
Coil Voltage
48VDC
Control On Voltage (max)
38.4 VDC
Control Off Voltage (min)
4.8 VDC
Mounting Type
Socket
Termination Style
Socketable
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
G2A432ADC48
Engineering Data
Maximum Switching Power
G2A AC (60 Hz)
G2A DC
Ambient Temperature vs.
Must-operate and Must-release
Voltage
Number of Relays: 5
Number of Relays: 5
DC inductive load
L/R = 7 ms
Switching voltage (V)
Ambient temperature (°C)
Ambient temperature (°C)
DC resistive load
http://www.ia.omron.com/
AC resistive load
AC inductive load
(cosφ = 0.4)
Must-operate
voltage
Must-release
voltage
Must-operate
voltage
Must-release
voltage
G2A DC
Ambient Temperature vs.
Coil Temperature Rise
G2A 110 VAC (50 Hz)
Number of Relays: 5
Number of Relays: 5
Ambient temperature (°C)
Ambient temperature (°C)
Endurance
10,000
5,000
1,000
Contact
carry current
Contact
carry current
500
100
50
10
110-VAC
inductive load
cosφ = 0.4
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
110-VAC
resistive load
Malfunctioning Shock
G2A-432A 100/110 VAC
Energized
Switching current (A)
24-VDC resistive load
Shock direction
Not energized
Number of samples = 5
Measurement conditions: Impose a shock of
100 m/s
times each with the Relay energized and not
energized to check the shock values that cause
the Relay to malfunction.
24-VDC
inductive load
L/R = 7 ms
2
in the ±X, ±Y, and ±Z directions three
Unit: m/s
2
G2A
4