Specifications of G2A-432A-DC48

Relay Type
General Purpose
Circuit
4PDT (4 Form C)
Contact Rating @ Voltage
0.5A @ 24VDC
Coil Type
Standard
Coil Current
22mA
Coil Voltage
48VDC
Control On Voltage (max)
38.4 VDC
Control Off Voltage (min)
4.8 VDC
Mounting Type
Socket
Termination Style
Socketable
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
G2A432ADC48
Safety Precautions for All Relays
Refer to the Safety Precautions section for each Relay for specific precautions applicable to that Relay.
■ Precautions for Safe Use
Observe the following precautions to
ensure safety.
• Do not touch the terminal section (charged section) of the Relay or
• Never use a Relay for a load that exceeds the contact ratings of the
• Do not drop the Relay or dismantle it. Doing so may reduce Relay
• Relay durability is greatly affected by the switching conditions.
• Do not apply an overvoltage or incorrect voltage to the coil, and do
• Do not use the Relay in atmospheres containing inflammable or
• Wire the Relay correctly according to the Precautions for Correct
Relay Application
• Before actually using the Relay, perform all possible tests to
• Unless otherwise specified, all ratings and performances given in
• All reference data provided in this catalog are from measurement
• All ratings and performances given in this catalog are from
Socket while power is being supplied. Electric shock may occur.
Relay, such as the switching capacity. Doing so may result in
reducing Relay performance for insulation failure, contact welding,
and contact faults, and might even result in burning or other
damage to the Relay itself.
performance and might even result in burning or other damage to
the Relay itself.
Always test the Relay under actual application conditions to confirm
applicability and use the Relay only for the number of switching
operations that will not affect performance. Continued application of
a Relay with reduced performance may result in insulation failure
between circuits or in burning in the Relay itself.
not wire the terminals incorrectly. Incorrect application may prevent
the Relay from performing its designed function, may affect
external circuits, and may even result in burning or other damage to
the Relay itself.
explosive gases. Switching arcs or Relay heating may result in fire
or explosion.
Use when performing wiring or soldering. If the Relay is used with
wiring or soldering that is defective, abnormal heating while power
is supplied may result in burning.
confirm applicability. Unexpected trouble can occur in actual
operation that would not be anticipated in theoretical planning.
this catalog are for JIS C5442 standard test conditions
(temperature: 15 to 35°C, humidity: 25% to 75%, pressure: 86 to
106 kPa). When testing the Relay in the actual application, use the
operating environment that will exist in actual applications along
with the actual load conditions.
samples taken from production lines and represented in graph
form. Actual values will depend on the application.
independent tests. Values will vary for different combinations of
ratings and performances.
http://www.ia.omron.com/
In the interest of product improvement, specifications are subject to change without notice.
■ Precautions for Correct Use
Refer to Technical Guide for General-purpose Relays.