NSH5-232UL-3M Omron, NSH5-232UL-3M Datasheet - Page 109

no-image

NSH5-232UL-3M

Manufacturer Part Number
NSH5-232UL-3M
Description
3m RS232 Cable For NSH5
Manufacturer
Omron
Datasheet

Specifications of NSH5-232UL-3M

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Installing NSH5-AL001 Removable Boxes enables using the station status monitor address function to create
an application like the one described in this section.
In this section, actual examples are given for creating applications, including the required CX-Designer set-
tings. The communications address and set values used in the following descriptions are only examples. The
user must adjust these examples to suit their own actual application conditions.
1. The screen that is displayed will change depending on the station number of the Removable Box connected
2. The PLC is notified of the station number of the Removable Box attached to the NSH5. (The method for
Connecting a Single NSH5 PT
The following description is for connecting a single NSH5. Use the following steps to set up the system.
1. Removable Box Setting
2. Station Status Monitor Address Settings
Removable
Boxes
Station 1
to the NSH5.
clearing the station number sent to the PLC when the NSH5 is not connected is also described.)
The station number for the Removable Box is set using the rotary switch. For setting details, refer to 4-2
Nomenclature and Functions and Functions and 4-3 Switch Settings.
Use the following procedure to enter settings in the CX-Designer.
(1) Select System Setting from the CX-Designer's PT Menu.
(2) Click the NS Handy Terminal Tab in the System Setting Dialog Box.
(3) Enter $W1000 in the Station Status Monitor Address Field
NSH5
Station 2
PLC
Screen 2
Removable Box Application Examples
DM00200 = 2
Station 3
Station 1 screen
(1) This screen will change depending on the station number of the
(2) The PLC is notified of the station number of the Removable Box
Screen 1
Removable Box that is connected to the NSH5.
that is attached to the NSH5. As a result, the PLC's processing
can be changed depending on the Removable Box's station
number. Here, the station number is stored in DM00200.
Appendix F
...
Station 2 screen
Screen 2
Station 8
...
Station 8 screen
Screen 8
87