MA3-4 BANNER ENGINEERING, MA3-4 Datasheet - Page 6

no-image

MA3-4

Manufacturer Part Number
MA3-4
Description
MA3-4 HG PLUG IN AMPLIFIER
Manufacturer
BANNER ENGINEERING
Datasheet

Specifications of MA3-4

Voltage, Supply
10-30 VDC
Accessory Type
Modulated Amplifier
Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Lead Free Status / Rohs Status
RoHS Exempt Product
For Use With
Remote Sensors
Banner Engineering Corp.
Sensor Hookup Diagrams for MA3-4 MICRO-AMP Modules
Accessories for High Performance Modulated Remote Sensors
Extension Cable
Modulated remote sensors require specially
designed cable for efficient sensor performance.
Extension cable is available in 100 foot (30m)
lengths.
Cable Protection
AC-6 6 feet (1,8m)
AC-30 30 feet (9m)
This is mild-steel flexible tubing
used with the compression fittings, at
right, to achieve maximum protection
to sensor cables.
I.D. = 5/16"; O.D. = 7/16".
Hookup of LR300 and PT300
Hookup of SP320D
9714 10th Avenue No., Minneapolis, MN 55441
Heavy duty PVC tubing used to
protect sensor cable in applications
involving moisture and/or corrosive
materials. I.D. = 1/4"; O.D. = 3/8".
PVC-6 6 feet (1,8m)
PVC-30 30 feet (9m)
Extension Cable
Model
ESC-100
RSC-100
SSC-100
EC300E-100
EC300R-100
EC320-100
Used on Sensor Models
PT200, PT250, PT400,
SP300RL
LR200, LR250, LR400,
SP300EL
SP300D, SP300L, LP400WB,
SP1000V
IMPORTANT : Cable Splicing Information
Remote sensor cables may be run up to 30 feet (9m) away from the MA3-4
amplifier. All sensor models are available from the factory with 30 feet of
cable, installed as an option.
When splicing additional cable to the standard 6-1/2 foot length, it is
important to use a separate shielded cable for emitter and receiver wires.
Combining emitter and receiver wires together in the same cable (even if
the cable is shielded) will result in direct coupling of the emitter signal to
the receiver leads.
This is called "cable crosstalk" and will not allow full amplifier sensitivity
setting without an amplifier "lock on" situation, which appears as a con-
tinuous LIGHT condition. Banner offers 100 foot (30m) lengths of sensor
extension cable (see below) which, if used for cable splicing, will minimize
the chances for cable crosstalk.
Telephone: (763) 544-3164
Hookup of SP300D, SP300L, LP400WB, SP1000V
Never use this product as a sensing device for personnel protection. Its
use as a safety device may create an unsafe condition which could lead
to serious injury or death.
Only MACHINE-GUARD and PERIMETER-GUARD Systems, and
other systems so designated, are designed to meet OSHA and ANSI
machine safety standards for point-of-operation guarding devices. No
other Banner sensors or controls are designed to meet these standards, and
they must NOT be used as sensing devices for personnel protection.
LR300
PT300
SP320D
WARNING
include the self-checking redundant circuitry neces-
sary to allow their use in personnel safety applica-
tions. A sensor or amplifier failure or malfunction
can result in either an energized or a de-energized
output condition.
FAX (applications): (763) 544-3573
# of
Wires
3
3
5
2
2
4
MICRO-AMP
White, Green, Shield
Red, Black, Shield
White, Green, Red, Black,
Shield
White, Shield
Red, Shield
White, Shield, Red, Shield
(continued)
Wire Colors
®
Systems do NOT

Related parts for MA3-4