RP-LM40D-6L BANNER ENGINEERING, RP-LM40D-6L Datasheet
RP-LM40D-6L
Specifications of RP-LM40D-6L
Related parts for RP-LM40D-6L
RP-LM40D-6L Summary of contents
Page 1
... Max. Rope Model Actuation Length RP-LM40D-6 Trip 6 m (20') RP-LM40D-6L Latch NOTE: This symbol for a positive opening safety contact (IEC 60947-5-1) is used in the switching diagrams to identify the point in actuator travel where the normally closed safety contact is fully open. Printed in USA Rope Pull Emergency Stop Switches ® ...
Page 2
... Administration (OSHA). Whether or not any particular safety switch installation meets all applicable OSHA requirements depends upon factors that are beyond the control of Banner Engineering Corp. These factors include the details of how the safety switches are applied, installed, wired, operated, and maintained. ...
Page 3
... Run condition (i.e., both contacts close) after releasing the rope, following a Pull condition; when using this model, a separate latching circuit is required. Model RP-LM40D-6L latches contacts 25–26 open with each Pull condition, and must be reset by pulling the integral reset button (see Figure 2) ...
Page 4
... Adjust the turnbuckle to tighten the rope, until contact 25—26 closes. This indicates sufficient rope tension. 6. Pull hard on the rope several times. If contact 25–26 remains open (following reset, for model RP-LM40D-6L), further tighten the turnbuckle, until contact 25–26 closes. 7. Repeat step #6 until contact 25–26 remains closed for the Run condition. 150 mm (6" ...
Page 5
... IMPORTANT: Model RP-LM40D-6 does not latch contacts 5–6 open when the rope is pulled. The contacts close when the rope is released. When using model RP-LM40D-6, a latch circuit must be included in the machine control circuitry. Maintenance Each rope pull emergency stop installation should be tested for proper machine shutdown response at each shift change or machine setup by a Designated Person* ...
Page 6
... M20 x 1.5 threaded entrance. Adapter supplied to convert M20 x 1.5 to ½"-14 NPT threaded entrance Construction Aluminum alloy die-cast Environmental Rating IEC IP65 Operating Conditions Temperature: Weight RP-LM40D-6: 0.22 Kg (0.49 lbs) RP-LM40D-6L: 0.26 Kg (0.57 lbs) Certifications 6 P/N 62082 rev. B RP-LM40 Series Specifications AWG (1 AWG (1 ...
Page 7
... Switch Models ½"-14 NPT Metal SI-QM-M0 Conduit Adaptor *NOTE: One conduit adapter is supplied with each switch. Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 SRP-LM40D-6 Dimensions Model RP-LM40D-6L 16.0 mm (0.63") 5.0 mm (0.20") Ø15.0 mm (0.59") 2.0 mm (0.08") 5.2 mm (0.20") Ø ...
Page 8
... Banner Engineering Corp. warrants its products to be free from defects for one year. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture found to be defective at the time it is returned to the factory during the warranty period. This warranty does not cover damage or liability for the improper application of Banner products ...