RP-LM40D-6L BANNER ENGINEERING, RP-LM40D-6L Datasheet - Page 5

no-image

RP-LM40D-6L

Manufacturer Part Number
RP-LM40D-6L
Description
RP-LM40D-6L 40mm ROPE PULL
Manufacturer
BANNER ENGINEERING
Type
Safetyr
Datasheet

Specifications of RP-LM40D-6L

Actuator Type
Latch
Body Style
Rectangular
Current, Rating
50 mA
Ip Rating
IP67
Number Of Positions
2
Voltage, Rating
10-30 VDC
Figure . Wire the two switch contacts in
Jumper Wire
Contacts
Between
Banner Engineering Corp. • Minneapolis, MN U.S.A.
Install
www.bannerengineering.com • Tel: 763.544.3164
series
13
25
14
26
Rope Pull Emergency Stop Switches –
To
Machine
Control
Stop
Circuit
Access to the Wiring Chamber
The wiring chamber is accessed via a cover plate (remove two screws). A conduit
adapter is supplied to convert the 20 millimeter threaded entrance to 1/2" NPT. An
accessory cable gland which fits the M20 thread is also available (see page 7).
Wiring
Install a jumper wire to place the two switch contacts in series, as shown in Figure 3.
IMPORTANT: Model RP-LM40D-6 does not latch contacts 5–6 open when the
rope is pulled. The contacts close when the rope is released. When using model
RP-LM40D-6, a latch circuit must be included in the machine control circuitry.
Each rope pull emergency stop installation should be tested for proper machine
shutdown response at each shift change or machine setup by a Designated Person*.
In addition, a Qualified Person* should check for proper rope tension, and adjust as
needed, on a periodic schedule determined by the user, based upon severity of the
operating environment and the frequency of switch actuations.
The pulleys and other moving parts associated with the rope should be periodically
lubricated. If inspection reveals dirt on the rope pull switch or rope assembly, the dirt
must be cleaned off and its cause must be eliminated. Replace the rope pull switch
and/or rope assembly when any parts (including contacts) or assemblies are found to be
damaged, broken, deformed, or badly worn.
The rope pull switch and rope assembly should be replaced at specified intervals based
upon the environment and operating conditions. Replacement of the rope pull switch and
rope assembly should be considered after no more than 500,000 operations. Always
test the control system for proper functioning under machine control conditions after
maintenance or replacement of the rope pull switch.
Banner rope pull emergency stop switches have no field-replaceable components.
Contact the Banner Factory Application Engineering Group at the address or the
numbers listed at the bottom of the back page. They will issue an RMA (Return
Merchandise Authorization) number for your paperwork, and give you the proper shipping
address.
* A Designated Person is identified in writing by the employer as being appropriately trained to
perform a specified checkout procedure. A Qualified Person possesses a recognized degree or
certificate or has extensive knowledge, training, and experience to be able to solve problems
relating to the emergency stop rope pull switch installation (reference ANSI B30.2).
Electrical Installation
Maintenance
Repairs
RP-LM40 Series
P/N 62082 rev. B
5