Specifications of ACM20-5-AC1-R-C

No. Of Digits / Alpha
4
Meter Function
AC Volts, Amps, Watts, And Power Factor
Digit Height
9.14mm
Supply Voltage Range
85VAC To 264VAC
Operating Temperature Range
0°C To +60°C
Input Current
RoHS Compliant
Meter Range
85V To 264V / 0A To 32A / 0W To 9999W / 47Hz To 63Hz
Power Consumption
250mW
Meter Output
Voltage
Rohs Compliant
Yes
TYPICAL WIRING DIAGRAMS, CONT.
Note: If the ACM20 displays zero Watts with
power applied to the load, reverse the direction
of the wire passing through the CT's center hole.
See Technical Note 6 for more information.
Note: If the ACM20 displays zero Watts with
power applied to the load, reverse the direction
of the wire passing through the CT's center hole.
See Technical Note 6 for more information.
Note: If the ACM20 displays zero Watts with
power applied to the load, reverse the direction
of the wire passing through the CT's center hole.
See Technical Note 6 for more information.
Epoxy encapsulation
Polarity dot on bottom
Figure 3. Wiring diagram for 220/240V systems with neutral (monitoring L1)
Figure 4. Wiring diagram for 220/240V systems with neutral (monitoring L2)
Epoxy encapsulation
Polarity dot on bottom
Epoxy encapsulation
Polarity dot on bottom
Figure 2. Wiring diagram for 220/240V systems with no neutral
www.murata-ps.com/dpm
220 V
LOAD
220 Vac (50/60 Hz)
L1 Neutral L2
L1 Neutral L2
220 Vac (50/60 Hz)
L1
220 Vac (50/60 Hz)
Fuse*
220 V
LOAD
220 V
LOAD
Fuse*
Fuse*
L2
03 Mar 2011 MPM_ACM20 Series.A09 Page 4 of 6