PQ60033ETL30PRS-G SYNQOR, PQ60033ETL30PRS-G Datasheet - Page 12

DC-DC CONVERTER, 3.3V

PQ60033ETL30PRS-G

Manufacturer Part Number
PQ60033ETL30PRS-G
Description
DC-DC CONVERTER, 3.3V
Manufacturer
SYNQOR
Datasheet

Specifications of PQ60033ETL30PRS-G

Dc / Dc Converter O/p Type
Fixed
No. Of Outputs
1
Input Voltage
35V To 75V
Output Voltage
3.3V
Output Current
30A
Supply Voltage
48V
Dc / Dc Converter Case Style
Eighth Brick
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Product # PQ60033ETL30
T
T
At time t
Lockout threshold. This disables the unit and initiates a Restart
Inhibit Period. During the Restart Inhibit Period, if the input volt-
age again exceeds the UVLO threshold, the unit cannot be
enabled again until the Restart Inhibit Period has elapsed. Once
this occurs, the output turns on with the Typical Turn-On Time.
At time t
Restart Inhibit Period. During the Restart Inhibit Period, if the
ON/OFF pin is again activated, the unit cannot be enabled
again until the Restart Inhibit Period has elapsed. Once this
occurs, the output turns on with the Typical Turn-On Time.
When the ON/OFF pin goes high after t
Period has elapsed, the output turns on approximately 1.6ms
after the ON/OFF pin is activated, with the Typical Turn-On Time.
If the Under-Voltage Lockout threshold has not been satisfied at
the end of either Inhibit Period, the unit will remain disabled until
the input voltage exceeds the UVLO threshold. Once this occurs,
the output turns on with the Typical Turn-On Time.
If the ON/OFF pin is activated after either Inhibit Period has
elapsed, the output will turn on approximately 1.6ms after the
ON/OFF pin is activated, with the Typical Turn-On Time.
echnical S
echnical S
Lockout Turn-On
Under-Voltage
ON/OFF
(pos logic)
Threshold
1
V out
2
V in
, the input voltage falls below the Input Under-Voltage
, the ON/OFF pin disables the unit and initiates a
ON
(typical start-up
inhibit period)
Figure F: Startup Inhibit Period (turn-on time not to scale)
10ms
t
0
pecification
pecification
Phone 1-888-567-9596
t
1
3
, and the Restart Inhibit
200ms
www.synqor.com
t
2
OFF
(typical restart
inhibit period)
200ms
ON
RoHS Compliance: The EU led RoHS (Restriction of Hazardous
Substances) Directive bans the use of Lead, Cadmium,
Hexavalent Chromium, Mercury, Polybrominated Biphenyls
(PBB), and Polybrominated Diphenyl Ether (PBDE) in Electrical
and Electronic Equipment. This SynQor product is available as
6/6 RoHS compliant.
SynQor’s RoHS addendum available at our RoHS Compliance /
Lead Free Initiative web page or e-mail us at rohs@synqor.com.
Doc.# 005-2ET633F Rev. A
t
3
OFF
200ms
P
P
For more information please refer to
Current:
Current:
ackage:
ackage:
Output:
Output:
Input:
Input:
ON
06/01/06
35-75 V
3.3 V
30 A
Eighth-brick
35-75 V
3.3 V
30 A
Eighth-brick
13.5ms
(typical turn on time)
t
Page 12