DV3100 DIGIVIEW, DV3100 Datasheet - Page 38

no-image

DV3100

Manufacturer Part Number
DV3100
Description
LOGIC ANALYSER, DIGITAL, 100MHZ, 18CH
Manufacturer
DIGIVIEW
Datasheet

Specifications of DV3100

No. Of Data Channels
18
No. Of Clock Inputs
8
Frequency
100MHz
Power Consumption
2.5W
External Height
0.75"
External Width
2.8"
External Depth
4.75"
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
34
DigiView User's Guide
2.3.2.1.1.5 Not Equal Match
The NOT Equal Match type is only available on DigiView DV3xxx series.
The NOT Equal Match Editor:
ADD a Signal - Highlight a defined signal from the left portion of the window and click the "+"
button to add it as the NOT Equal Match. You can also just "Double-Click" the defined signal to
automatically add it. NOTE: High Level signal definitions (such as State, I2C, or etc) cannot be
added directly as a complete signal. However, the individual portions of the signal (such as the
DATA portion of a State Signal) can be added in the same manner. To see the sub-portions of a
signal, click the "expand" button in the left column next to the signal's name, then add the sub
portion in the same manner as any other signal.
For instance, if you have defined a Synchronous Serial signal (i.e. SPI) and you want to add the
:Enable portion of the signal to the NOT Equal match, then expand it and double-click on :Enable.
It would then appear on the right portion of the editor.
The NOT Equal Match type only accepts one signal at a time. After a signal has been added, the
"+" (ADD) button will be disabled (as shown above) until the current signal is removed.
Delete a Signal - Highlight a signal in the right portion of the window (or mouse-over its bit
selections) and click the "-" button to delete it from the NOT Equal Match.
Match Value Format - The value for the Not Equal Match type can be entered in Decimal, HEX,
Binary or ASCII format. The value will be limited to the maximum value allowed for the selected