DV3100 DIGIVIEW, DV3100 Datasheet - Page 56
DV3100
Manufacturer Part Number
DV3100
Description
LOGIC ANALYSER, DIGITAL, 100MHZ, 18CH
Manufacturer
DIGIVIEW
Datasheet
1.DV3100.pdf
(125 pages)
Specifications of DV3100
No. Of Data Channels
18
No. Of Clock Inputs
8
Frequency
100MHz
Power Consumption
2.5W
External Height
0.75"
External Width
2.8"
External Depth
4.75"
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3.1
52
Capture Troubleshooting
DigiView User's Guide
1. DigiView (DV1-100, DV3100) Power LED
does not stay ON.
2. DigiView is only identified as a SERIAL
device by the USB subsystem.
3. One of DigiView's channels is connected to
a transitioning signal, but the capture does not
seem to show any activity or very little activity.
Symptom
(A). The USB subsystem of the PC is turning
DigiView Off due to a Bandwidth shortage.
REMEDY: Remove other USB devices that
use a port on the same hub (internal or
external).
(B). The USB subsystem of the PC is turning
DigiView Off or DigiView is resetting due to
insufficient power.
REMEDY: If you are using an external hub,
change to a POWERED external hub or
purchase one of better quality that meets USB
specifications.
(A). The USB sub-system is experiencing a
problem with corrupted or missing files.
REMEDY: Look for a driver update to the USB
hub (internal or external) or re-install its
drivers. Refresh the DigiView drivers by
re-installing the DigiView software.
(B). Operating System or computer needs
rebooted.
REMEDY: Turn off the computer and re-boot
the system.
(C). The DigiView hardware has been
damaged.
REMEDY: Call Technical Support for repair
information.
(A). The resolution of the Waveform View is
too low to see the activity.
REMEDY: Zoom In to see the details of the
activity.
(B). The signal has been defined with the
wrong channel selected.
Causes & Solutions
© 2010 TechTools