72-8170 TENMA, 72-8170 Datasheet - Page 6

MULTIMETER, ANALOG, 6 FUNCTIONS

72-8170

Manufacturer Part Number
72-8170
Description
MULTIMETER, ANALOG, 6 FUNCTIONS
Manufacturer
TENMA
Datasheet

Specifications of 72-8170

Voltage Measuring Range Dc
600mV - 1000V
Voltage Measuring Range Ac
600mV - 1000V
Current Measuring Range Dc
120µA To 10A
Range Selection
Manual
External Height
6.7"
External Width
4.9"
Lead Free Status / RoHS Status
na
Replacing the Fuse
Replace the rear housing and reinstall the screws.
Make certain the test leads are removed from the circuit under test and disconnected
from the meter.
Remove the three Philips head screws from the rear of the meter housing
Remove the rear housing from the meter assembly.
Locate and replace the fuse in its socket located on the surface of the internal PC
board.
Replace with only a comparable 5mm x 20mm 0.5A 250V fast blow type fuse.
Replace the rear housing and reinstall the screws.
Important Note: Replacement of the fuses is seldom required. A blown fuse is always a
direct result from improper meter use.
Springboro, Ohio 45066
Tenma Test Equipment
405 S. Pioneer Blvd.
www.tenma.com