M250A GOSSEN METRAWATT, M250A Datasheet - Page 5

MULTIMETER METRAHIT E-XTRA

M250A

Manufacturer Part Number
M250A
Description
MULTIMETER METRAHIT E-XTRA
Manufacturer
GOSSEN METRAWATT
Datasheets

Specifications of M250A

Dmm Type
Handheld
Voltage Measuring Range Dc
1000V
Voltage Measuring Range Ac
1000V
Current Range Dc
600µA To 10A
Current Range Ac
600µA To 10A
Resistance Measuring Range
600R - 60MR
Frequency
RoHS Compliant
Frequency Measuring Range
600Hz - 1MHz
Capacitance Measuring Range
60nF -
Rohs Compliant
NA
Power Supply
Battery
Service life
Battery test
Power OFF function
Power pack socket
(METRAHIT E
Display
LCD panel (65 mm x 36 mm) with analog and digital display includ-
ing unit of measure, type of current and various special functions
Background illumination
Background illumination is switched off approximately 1 minute
after it has been activated.
Analog
Display
Scaling
Polarity display
Overflow display
Measuring rate
Digital
Display / char. height 7-segment characters / 15 mm
Resolution
Overflow display
Polarity display
Measuring rate
Refresh rate
Acoustic Signals
For voltage
For current
GMC-I Gossen-Metrawatt GmbH
XTRA
)
2 ea. 1.5 V mignon cell (2 ea. size AA),
alkaline manganese per IEC LR6
(2 ea. 1.2 V NiMH rechargeable battery
also possible)
with alkaline manganese: approx. 200
hours
Battery capacity display with battery
symbol in 4 segments:
Querying of momentary battery voltage via
menu function.
Multimeter is switched off automatically:
– If battery voltage drops to below prox. 1.8 V
– If none of the keys or the rotary switch
If the NA X-TRA power pack has been
plugged into the instrument, the batteries
are disconnected automatically.
Rechargeable batteries can only be
recharged externally.
LCD scale with bar graph or pointer, depend-
ing on the selected parameter setting
With 4 division lines each, 1 bar/pointer cor-
responds to 500 counts at the digital display
With automatic switching
With the
40 measurements per second and display
refresh
59,999 counts
“OL” is displayed for ≥ 60,000 counts
“–” (minus sign) is displayed
if plus pole is connected to “⊥”
10 or 40 measurements per second with
the Min-Max function except for the
capacitance, frequency and duty cycle
measuring functions
2 times per sec., every 500 ms
Intermittent signal at above 1000 V
Intermittent signal at above 10 A
continuous signal at above 16 A
are activated for an adjustable duration
of 10 to 59 minutes, and the multimeter
is not in the continuous operation mode
symbol
METRAHIT⏐E
.
Fuse for METRAHIT E
Fuse
Electrical Safety
Per IEC 61010-1:2001/VDE 0411-1:2002
METRAHIT E
Safety class
Measuring category
Operating voltage
Pollution degree
Test voltage
METRAHIT E
Special device for measurements at current transformers without
fuse in the electrical circuit
Safety class
Measuring category
Pollution degree
Test voltage
Electromagnetic Compatibility (EMC)
Interference emission EN 610326-1: 2006, class B
Interference immunity EN 610326-1: 2006
Ambient Conditions
Accuracy range
Operating temp. range −10 °C ... +50 °C
Storage temp. range −25 °C ... +70 °C (without batteries)
Relative humidity
Elevation
Deployment
Mechanical Design
Housing
Dimensions
Weight
Protection
(1
st
IP XY
digit X)
5
XTRA
TRMS Digital Multimeters
XTRA
SPECIAL
Protection against pene-
tration of solid particles
, METRAHIT E
⏐E
Dust protected
„for Current Transformers“
TECH
FF (UR) 10 A/1000 V AC/DC;
10 mm x 38 mm,
Switching capacity: 30 kA at 1000 V AC/
DC, protects the current measurement
input in the 600 μA through 10 A ranges
III
1000 V
II
600 V CAT II
2
3.5 kV~
EN 61000-4-3: 2006
Evaluation criterion B
Max.75%, no condensation allowed
To 2000 m
Indoors, except within specified ambient
conditions
Impact resistant plastic (ABS)
200 x 87 x 45 mm
(without protective rubber holster)
Approx. 0.35 kg with batteries
Housing: IP 52 (pressure equalization by
means of the housing)
Table excerpt regarding significance of the
IP code
XTRA
0 °C ... +40 °C
TECH
⏐E
, METRAHIT E
, METRAHIT E
II
2
6.7 kV~
(2
nd
SPECIAL
IP XY
digit Y)
2
IV
600 V
BASE
Dripping (15° inclination)
penetration by water
TECH
Protection against
⏐E
BASE
5