P01196787 CHAUVIN ARNOUX, P01196787 Datasheet - Page 6

no-image

P01196787

Manufacturer Part Number
P01196787
Description
MULTIMETER, DIGITAL, TRUE RMS AC CA5287
Manufacturer
CHAUVIN ARNOUX
Datasheet

Specifications of P01196787

Dmm Type
Handheld
Voltage Measuring Range Dc
50mV-1000V
Voltage Measuring Range Ac
50mV-1000V
Current Range Dc
500 µA - 10A
Current Range Ac
500 µA - 10A
Resistance Measuring Range
500
Frequency Measuring Range
99.999Hz To 999.99kHz
Rohs Compliant
NA
Lead Free Status / RoHS Status
na
n
The accuracy is expressed as ± (% of reading + number of counts of least significant digit) at 23°C ± 5 °C, with a relative humidity of less
than 80 %.
n
n
n
50,000-count TRMS AC/DC multimeter
Screen
Functions
Modes
Operating temperature
Storage temperature
Relative humidity (RH)
Temperature coefficient
Common mode rejection rate (CMRR)
Normal mode rejection rate (NMRR)
Power supply
Battery life
Communication interface
Electrical safety
Electromagnetic compatibility
Dimensions
Poids
6
General specifications
DC Voltage
AC Voltage (root mean square value: 5 % to 100 % of the range)
dB (calculation of decibels)
1,000 mV
Base for dB
1 mW (dBm)
500 mV
1,000 mV
50 mV
1 V (dBV)
500 mV
1,000 V
1,000 V
Range
Range
50 mV
500 V
500 V
50 V
50 V
5 V
5 V
(1)
(1)
(1)
(1) Protection 1,000 Vrms for Ip-p < 0.3 A
(18) The accuracy is ± (0.05 % +5) if the relative function is used to offset the thermal effect (short test leads) before measuring the signal.
(19) For voltages of less than 200 Vrms, add 40 counts: 1.6 % + 40
(20) For voltages of less than 200 Vrms, add 40 counts: 1.0 % + 40
Resolution
Resolution
1 to 9 999 Ω
0.001 mV
0.0001 V
0.001 mV
0.0001 V
Reference
0.01 mV
0.01 mV
0.001 V
0.001 V
0.1 mV
0.1 mV
0.01 V
0.01 V
0.1 V
0.1 V
1 V
30~45 Hz
reference
1 % + 60
1 % + 60
1 % + 60
1 % + 60
1 % + 60
1 % + 60
1 % + 60
0.05 % + 50
Default
600 Ω
0.03 % + 5
1 V
Accuracy
Dual LCD display, 51,000 counts, 21-segment bargraph
Automatic polarity indication – Backlighting
V
I
Ω, nS
Audible continuity, semi-conductor test
°C, °F, Hz
Duty cycle / Pulse width
dBm, dBV
Min/Max/Avg, HOLD, Auto-HOLD, REL, PEAK 1 ms
0°C to +50°C
-20 °C to +60 °C with battery removed
Maximum 80 % RH for temperatures up to 31 °C diminishing linearly to 50 % HR at 50 °C
0.15 x (specified accuracy) /°C (0 °C to 18 °C or 28 °C to 50 °C)
> 90 dB with DC, 50/60 Hz ± 0.1 % (1 kΩ unbalanced)
> 60 dB to 50/60 Hz ± 0.1 %
One standard 9 V alkaline or carbon zinc battery.
Integrated system for management of rechargeable 9 V Ni-MH batteries
80 hours for DC voltage measurement (approx.) (9 V alkaline battery / 545 mAH).
With indication of the battery capacity.
Two-way optical link. SCPI command instructions.
NF EN 61010-1 (2001) and NF EN 61010-2-32 (2002) for 1,000 V CAT III or 600 V CAT IV, pollution degree 2
Complies with the standard on electromagnetic compatibility as per NF EN 61326-1 (07/97) + A1 (10/98) +A2 (09/2001)
44 (H) x 103 (l) x 203 (L) mm
680 grams with battery
ac
ac
, I
, V
dc
dc
(18)
0.6 % + 40
0.6 % + 25
0.6 % + 25
0.6 % + 25
0.6 % + 25
0.6 % + 25
0.6 % + 40
45~1 kHz
Remarks
The power decibels display uses the reference 1 mW whereas the voltage decibels display uses the reference 1 V.
Although the formula shows that the accuracy of the result depends on the accuracy of the voltage measurement, an additional
error of 0.3 dB should be added due to the calculation.
Autoranging is used for measurements in decibels. The bandwidth depends on the voltage measurement.
Accuracy
Protection against overloads
1 k~10 kHz
1.0 % + 40
1.0 % + 40
1.0 % + 25
1.0 % + 25
1.0 % + 25
1.0 % + 25
1.0 %
1,000 V
1,000 V
(20)
(1)
10 k~30 kHz
1.6 % + 60
1.6 % + 60
1.6 % + 40
1.6 % + 40
1.6 % + 40
1.6 %
No spec.
(19)
C.A 5287
- Input impedance
• for the ranges from 50 mV to 1,000 mV: > 1 GΩ
• for the ranges from 5 V to 1,000 V: 10 MΩ (nominal) with
- Input impedance:
• for the ranges from 50 mV to 1,000 mV: > 1 GΩ.
• for the ranges from 5 V to 1,000 V: 1.1 MΩ (nominal) in
- Crest factor: ≤ 3
single display or 1.1 MΩ with double display
parallel with <100 pF (nominal)