P01196787 CHAUVIN ARNOUX, P01196787 Datasheet - Page 8

no-image

P01196787

Manufacturer Part Number
P01196787
Description
MULTIMETER, DIGITAL, TRUE RMS AC CA5287
Manufacturer
CHAUVIN ARNOUX
Datasheet

Specifications of P01196787

Dmm Type
Handheld
Voltage Measuring Range Dc
50mV-1000V
Voltage Measuring Range Ac
50mV-1000V
Current Range Dc
500 µA - 10A
Current Range Ac
500 µA - 10A
Resistance Measuring Range
500
Frequency Measuring Range
99.999Hz To 999.99kHz
Rohs Compliant
NA
Lead Free Status / RoHS Status
na
n
n
Sensitivity for voltage
Sensitivity according to the frequency and trigger level
Duty cycle
Pulse width
Sensitivity for current
Maximum input: please refer to AC current measurement.
FRANCE
Chauvin Arnoux
190, rue Championnet
75876 PARIS Cedex 18
Tel: +33 1 44 85 44 86
Fax: +33 1 46 27 95 59
export@chauvin-arnoux.fr
www.chauvin-arnoux.fr
50,000-count TRMS AC/DC multimeter
Thermocouple
Temperature
Frequency
9.9999 kHz
99.999 kHz
999.99 kHz
99.999 Hz
999.99 Hz
0.01 %~99.99 %
Input range
Range
5,000 µA
type
500 mA
2,000 ms
500 µA
50 mA
500 ms
K
Range
10 A
5 A
Range
accuracy = 10 x range or 1,000 V)
(Maximum input for specified
-200 °C ~ +1 372 °C
-328 °F ~ +2 502 °F
Resolution
0.0001 kHz
0.001 kHz
0.001 Hz
0.01 kHz
0.01 Hz
Input range
1,000 mV
500 mV
1,000 V
50 mV
500 V
50 V
Minimum sensitivity
Range
5 V
Resolution
Accuracy of full scale
0.3 %
0.01 ms
0.1 ms
UNITED KINGDOM
Chauvin Arnoux Ltd
Waldeck House - Waldeck Road
MAIDENHEAD SL6 8BR
Tel: +44 1 628 788 888
Fax: +44 1 628 628 099
info@chauvin-arnoux.co.uk
www.chauvin-arnoux.co.uk
par
0.02 % + 3
Accuracy
< 600 kHz
kHz + 0.3 %
20 Hz-20 kHz
Resolution
100 µA
250 µA
10 mA
25 mA
2.5 A
1 A
0.1 °C
0.1 °F
(rms value – sine wave)
Min. Input Frequency
Accuracy
0.2 % + 3
DC coupling
0.3 % + 3 °C
0.3 % + 6 °F
1 Hz
Minimum sensitivity
20 Hz-100 kHz
Accuracy
Mode
10 mV
25 mV
40 mV
0.25 V
2,5 V
25 V
50 V
MIDDLE EAST
Chauvin Arnoux Middle East
P.O. BOX 60-154
1241 2020 JAL EL DIB (Beirut) - LEBANON
Tel: +961 1 890 425
Fax: +961 1 890 424
camie@chauvin-arnoux.com
www.chauvin-arnoux.com
The accuracy does not include the tolerance of the probe, and the temperature
probe connected to the multimeter must be placed in the location where it will be
used at least 1 hour in advance.
The maximum acceptable voltage is determined by the following formula: [Voltage of
signal measured] x [Frequency of signal measured] < 20,000,000
without exceeding 1,000 V.
The accuracy for the duty cycle and pulse width is based on one 5 V square-
signal input on the 5 V
For AC coupling, the duty cycle range can be measured at 5 % ~ 95 % of the
full range if the frequency of the signal is > 20 Hz.
The positive or negative pulse width must be greater than 10 µs and the duty
cycle should be taken into account. The pulse width scale is determined by the
signal’s frequency.
> 100 kHz~ 200 kHz
(rms value – sine wave)
No spec.
No spec.
15 mV
35 mV
50 mV
0.5 V
5 V
dc
range.
0.5 V / 1.25 V <100 Hz
For assistance and ordering
< 100 kHz
100 mV
10 mV
60 mV
300 V
50 V
5 V
Trigger level for DC coupling
C.A 5287
> 100kHz ~ 200 kHz
No spec.
No spec.
150 mV
15 mV
70 mV
0.6 V
6 V