E4404B STD AGILENT TECHNOLOGIES, E4404B STD Datasheet - Page 2

ANALYZER, SPECTRUM, 9KHZ To 6.7GHZ

E4404B STD

Manufacturer Part Number
E4404B STD
Description
ANALYZER, SPECTRUM, 9KHZ To 6.7GHZ
Manufacturer
AGILENT TECHNOLOGIES
Datasheet

Specifications of E4404B STD

Spectrum Analyzer Type
Bench
Frequency Measuring Range
9kHz To 6.7GHz
Sensitivity Dbm
-139dBm
External Height
222mm
External Width
416mm
External Depth
409mm
Weight
37.7lb
Lead Free Status / RoHS Status
na
Definitions and Conditions
The distinction between specifications and
characteristics is described as follows.
• Specifications describe the performance of
• Characteristics describe product performance that
• Typical performance describes additional product
• Nominal values indicate the expected performance,
• N/A (not applicable) - Not specified for this
The following conditions must be met for the analyzer
to meet its specifications.
• The analyzer is within the one year calibration
• If Auto Align All is selected:
• If Auto Align Off is selected:
• If Auto Align All but RF is selected:
2
parameters covered by the product warranty.
(The temperature range is 0 °C to 55 °C, unless
otherwise noted.)
is useful in the application of the product, but is
not covered by the product warranty.
performance information that is not covered by the
product warranty. It is performance beyond
specification that 80% of the units exhibit with
a 95% confidence level over the temperature range
20 to 30 °C. Typical performance does not include
measurement uncertainty.
or describe product performance that is useful in
the application of the product, but is not covered
by the product warranty.
configuration
cycle.
• After 2 hours of storage within the operating
• 5 minutes after the analyzer is turned on with
• When the analyzer is at a constant temperature,
• After the analyzer is turned on for a minimum
• When Align Now All is run:
• When the analyzer is at a constant temperature,
• After the analyzer is turned on for a minimum
• When Align Now RF is run:
temperature range.
sweep times less than 4 seconds.
within the operating temperature range, for a
minimum of 90 minutes.
of 90 minutes and Align Now All has been run.
• Every hour
• If the ambient temperature changes more
• If the 10 MHz reference changes
within the operating temperature range, for a
minimum of 90 minutes.
of 90 minutes and Align Now RF has been run.
• Every hour
• If the ambient temperature changes more
than 3 °C
than 3 °C
Table of Contents
Definitions and Conditions
Frequency Specifications
Amplitude Specifications
Tracking Generator Specifications
Quasi-Peak Detector Specifications
General Specifications
Option Ordering