ISL5585FCRZ Intersil, ISL5585FCRZ Datasheet - Page 19

no-image

ISL5585FCRZ

Manufacturer Part Number
ISL5585FCRZ
Description
SLIC 1-CH 53dB 45mA 3.3V/-18V/-24V/-28V 32-Pin QFN EP
Manufacturer
Intersil
Datasheet

Specifications of ISL5585FCRZ

Package
32QFN EP
Number Of Channels Per Chip
1
Polarity Reversal
Yes
Longitudinal Balanced
53(Min) dB
Loop Current
45 mA
Minimum Operating Supply Voltage
2.97|-16 V
Typical Operating Supply Voltage
3.3|-18|-24|-28 V
Typical Supply Current
9.3 mA
When the forward loop back mode is initiated internal
switches connect a 600Ω load across the outputs of the Tip
and Ring amplifiers.
FIGURE 13. FORWARD LOOP BACK INTERNAL TERMINATION
RING
TIP
600Ω
19
TIP AMP
RING AMP
ISL5585
DC Verification
When the internal signal path is provided, DC current will
flow from Tip to Ring. The DC current will force DET low,
indicating the presence of loop current. In addition, the ALM
output will also go low. This does not indicate a thermal
alarm condition. Rather, proper logic operation is verified in
the event of a thermal shutdown. In addition to verifying
device functionality, toggling the logic outputs verifies the
interface to the system controller.
AC Verification
The entire AC loop of the device is active during the forward
loop back mode. Therefore a 4-wire to 4-wire level test
capability is provided. Depending on the transhybrid balance
implementation, test coverage is provided by a one or two
step process.
System architectures which cannot disable the transhybrid
function would require a two step process. The first step
would be to send a test tone to the device while on hook and
not in forward loop back mode. The return signal would be
the test level times the gain R
amplifier. Since the device would not be terminated,
cancellation would not occur. The second step would be to
program the device to FLB and resend the test tone. The
return signal would be much lower in amplitude than the first
step, indicating the device was active and the internal
termination attenuated the return signal. System
architectures which disable the transhybrid function would
achieve test coverage with a signal step. Once the
transhybrid function is disable, program the device for FLB
and send the test tone. The return signal level is determined
by the 4-wire to 4-wire gain of the device.
Tip Open
Overview
The tip open mode (110) is intended for compatibility for PBX
type interfaces. Used during idle line conditions, the device
does not provide transmission. Loop supervision is provided
by either the switch hook detector (E0 = 1) or the ground key
detector (E0 = 0). The ground key detector will be used in
most applications. The device may be operated from either
high or low battery.
Functionality
During tip open operation, the Tip switch is disabled and the
Ring switch is enabled. The minimum Tip impedance is
30kΩ. The only active path through the device will be the
Ring switch.
In keeping with the MTU characteristics of the device, Ring
will not exceed -56V when operating from the high battery.
Though MTU does not apply to tip open, safety requirements
are satisfied.
F
/R
A
of the transhybrid

Related parts for ISL5585FCRZ