M29W128GH70ZA6E NUMONYX, M29W128GH70ZA6E Datasheet - Page 31

no-image

M29W128GH70ZA6E

Manufacturer Part Number
M29W128GH70ZA6E
Description
Flash Mem Parallel 3V/3.3V 128M-Bit 16M x 8/8M x 16 70ns 64-Pin TBGA Tray
Manufacturer
NUMONYX
Datasheet

Specifications of M29W128GH70ZA6E

Package
64TBGA
Cell Type
NOR
Density
128 Mb
Architecture
Sectored
Block Organization
Symmetrical
Typical Operating Supply Voltage
3|3.3 V
Sector Size
128KByte x 128
Timing Type
Asynchronous
Operating Temperature
-40 to 85 °C
Interface Type
Parallel

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M29W128GH70ZA6E
Manufacturer:
ST
0
Part Number:
M29W128GH70ZA6E
Manufacturer:
ST
Quantity:
20 000
M29W128GH, M29W128GL
Command interface
6.1.10
Program command
The Program command can be used to program a value to one address in the memory
array at a time. The command requires four bus write operations, the final write operation
latches the address and data in the internal state machine and starts the program/erase
controller.
Programming can be suspended and then resumed by issuing a Program Suspend
command and a Program Resume command, respectively (see
Section 6.1.8: Program
Suspend command
and
Section 6.1.9: Program Resume
command).
If the address falls in a protected block then the program command is ignored, the data
remains unchanged. The status register is never read and no error condition is given.
After programming has started, bus read operations output the status register content. See
Figure 17: Write enable controlled program waveforms (8-bit mode)
and
Figure 18: Write
enable controlled program waveforms (16-bit mode)
for more details. Typical program times
are given in
Table 17: Program, erase times and program, erase endurance
cycles.
After the program operation has completed the memory will return to the read mode, unless
an error has occurred. When an error occurs, bus read operations to the memory continue
to output the status register. A Read/Reset command must be issued to reset the error
condition and return to read mode.
One of the erase commands must be used to set all the bits in a block or in the whole
memory from ’0’ to ’1’.
The program operation is aborted by performing a reset or powering-down the device. In
this case data integrity cannot be ensured, and it is recommended to reprogram the word or
byte aborted.
31/94

Related parts for M29W128GH70ZA6E