PKM4111DPINB Ericsson Power Modules, PKM4111DPINB Datasheet - Page 16

Module DC-DC 1-OUT 5V 25A 125W 8-Pin Quarter-Brick Box

PKM4111DPINB

Manufacturer Part Number
PKM4111DPINB
Description
Module DC-DC 1-OUT 5V 25A 125W 8-Pin Quarter-Brick Box
Manufacturer
Ericsson Power Modules
Type
Step Downr
Series
PKM-Dr
Datasheet

Specifications of PKM4111DPINB

Package
8Quarter-Brick
Output Current
25 A
Output Voltage
5 V
Input Voltage
36 to 75 V
Number Of Outputs
1
Output Power
125 W
Product
Isolated
Input Voltage Range
36 V to 75 V
Output Voltage (channel 1)
1.5 V
Output Current (channel 1)
20 A
Isolation Voltage
1.5 KV
Package / Case Size
Quarter Brick
Output Type
Isolated
Lead Free Status / Rohs Status
 Details

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PKM4111DPINB
Manufacturer:
VICOR
Quantity:
1 000
E
Operating information continued
Parallel Operation
The PKM 4000DSeries DC/DC converters can be paralleled
for redundancy if external o-ring diodes are used in series
with the outputs. It is not recommended to parallel the PKM
4000D Series DC/DC converters for increased power without
using external current sharing circuits.
See Design Note 006 for detailed information.
Remote Sense
All PKM 4000DSeries DC/DC converters have remote sense
that can be used to compensate for moderate amounts of
resistance in the distribution system and allow for voltage
regulation at the load or other selected point. The remote
sense lines will carry very little current and do not need a
large cross sectional area. However, the sense lines on the
Pcb should be located close to a ground trace or ground
plane. In a discrete wiring situation, the use of twisted pair
wires or other technique to reduce noise susceptibility is
highly recommended. The remote sense circuitry will
compensate for up to 10% voltage drop between the sense
voltage and the voltage at the output pins. The output voltage
and the remote sense voltage offset must be less than the
minimum over voltage trip point. If the remote sense is not
needed the —Sense should be connected to —Out and +Sense
should be connected to +Out.
Over Temperature Protection (OTP)
The PKM 4000DSeries DC/DC converters are protected from
thermal overload by an internal over temperature shutdown
circuit. When the Pcb temperature (TC reference point)
exceeds the temperature trig point (120 °C) for the OTP
circuit the converter will cut down output power. The
converter will go into hiccup mode until safe operational
temperature is restored.
Over Voltage Protection (OVP)
The PKM 4000DSeries DC/DC converters include output
overvoltage protection. In the event of an overvoltage
condition due to malfunction in the voltage monitoring
circuits, the converter's PWM will automatically dictate
minimum duty-cycle thus reducing the output voltage to a
minimum.
Over Current Protection (OCP)
The PKM 4000DSeries DC/DC converters include current
limiting circuitry that allows them to withstand continuous
overloads or short circuit conditions on the output. The
output voltage will decrease towards zero for output currents
in excess of max output current (Iomax).
The converter will resume normal operation after removal of
the overload. The load distribution system should be
designed to carry the maximum output short circuit current
specified.
ESKEVIN
Approved
SEC/D (Julia You)
PKM 4000D PINB series Direct Converters
Input 36-75 V, Output up to 40 A/120 W
Checked
EYINGJI
output section. The test is done in a wind tunnel with a cross
mounted on a 16 layer Pcb with a size of 254 x 254 mm, each
layer with 35 μm (1 oz) copper. Proper cooling can be verified
by measuring the temperature of selected devices. Peak
temperature can occur at positions P1 - P4. The temperature
at these positions should not exceed the recommended max
values.
See Design Note 019 for further information.
Thermal Consideration
General
The PKM 4000DSeries DC/DC converters are designed to
operate in a variety of thermal environments, however
sufficient cooling should be provided to help ensure reliable
operation. Heat is removed by conduction, convection and
radiation to the surrounding environment. Increased airflow
enhances the heat transfer via convection. The available load
current vs. ambient air temperature and airflow at Vin =53 V
for each model is according to the information given under the
section of 305 x 305 mm, the DC/DC converter vertically
3/1301-BMR 637 02 Uen
Date
2007-12-10
Position
P
P
P
P
1
2
3
4
Device
Pcb
Mosfet
Mosfet
Transformer
Technical Specification
EN/LZT 146 306 R4D December 2009
© Ericsson AB
Rev
B
Designation
T
Tsurface
Tsurface
Tsurface
ref
Reference
max value
110º C
120º C
120º C
130º C
16