PKM4319EPI Ericsson Power Modules, PKM4319EPI Datasheet - Page 32

Module DC-DC 1-OUT 2.5V 15A 37.5W 8-Pin Quarter-Brick

PKM4319EPI

Manufacturer Part Number
PKM4319EPI
Description
Module DC-DC 1-OUT 2.5V 15A 37.5W 8-Pin Quarter-Brick
Manufacturer
Ericsson Power Modules
Type
Step Downr
Series
PKM-Er
Datasheet

Specifications of PKM4319EPI

Package
8Quarter-Brick
Output Current
15 A
Output Voltage
2.5 V
Input Voltage
36 to 75 V
Number Of Outputs
1
Output Power
37.5 W
Product
Isolated
Input Voltage Range
36 V to 75 V
Output Voltage (channel 1)
1.5 V
Output Current (channel 1)
20 A
Isolation Voltage
1.5 KV
Package / Case Size
Quarter Brick
Output Type
Isolated
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PKM4319EPI
Manufacturer:
ERICSSON
Quantity:
5
EMC Specification
The conducted EMI measurement was performed using a
module placed directly on the test bench .
The fundamental switching frequency is 180 kHz for
PKM4510E PI @ V
External filter (class B)
Required external input filter in order to meet class B in
EN 55022, CISPR 22 and FCC part 15J .
PKM 4510 E PI without filter
PKM 4510 E PI with filter
PKM 4000E PI Datasheet
Conducted EMI Input terminal value (typ)
I
= 53V, I
O
= (0 .1 . . .1 .0) x I
O
max .

Test set-up.
Layout Recommendation
The radiated EMI performance of the DC/DC converter
will be optimised by including a ground plane in the PCB
area under the DC/DC converter . This approach will re-
turn switching noise to ground as directly as possible, with
improvements to both emissions and susceptibility . It is also
important to consider the stand-off of the PKM 4000E series
DC/DC converter . If one ground trace is used, it should be
connected to the input return . Alternatively, two ground
traces may be used, with the trace under the input side of
the DC/DC converter connected to the input return and the
trace under the output side of the DC/DC converter con-
nected to the output return . Make sure to use appropriate
safety isolation spacing between these two return traces .
The use of two traces as described will provide the capabil-
ity of routing the input noise and output noise back to their
respective returns .
Output ripple and noise
The circuit below has been used for the ripple and noise
measurements on the PKM 4000E Series DC/DC converters .
DC
Power
Source
* Conductor from Vout to capacitors = 50mm [1.97in]
+
-
50 ohm input
in
in
5µH 50Ω
5µH 50Ω
LISN
LISN
+Sense
-Sense
+Vout
Output ripple and noise test setup
-Vout
EN/LZT 146 051 R7A © Ericsson Power Modules, February 2007
Trim
rcvr
rcvr
EMC
Reciver
out
out
1 m Twisted Pair
Optional Connection
to Earth Ground
50 ohm temination
Ceramic
Capacitor
0.1uF
Filter
(if used)
Computer
Tantalum
Capacitor
Printed Circuit Board
+
10uF
Power Module
BNC
Connector
to Scope
Load
Resistive
Load