1423155-5 Tyco Electronics, 1423155-5 Datasheet - Page 3

no-image

1423155-5

Manufacturer Part Number
1423155-5
Description
Electromechanical Relay SPDT 10A 125VDC Socket
Manufacturer
Tyco Electronics
Type
Control Relayr
Series
GP, AGASTATr
Datasheet

Specifications of 1423155-5

Contact Arrangement
SPDT
Dc Coil Voltage
125 V
Mounting
Socket
Relay Type
General Purpose
Contact Form
SPDT (1 Form C)
Contact Rating (current)
10A
Switching Voltage
220VAC
Coil Type
Standard
Coil Voltage
125VDC
Mounting Type
Socket
Termination Style
Socketable
Circuit
SPDT (1 Form C)
Contact Rating @ Voltage
10A @ 220VAC
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Coil Current
-
Control On Voltage (max)
-
Control Off Voltage (min)
-
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
GPD
Specifications subject to change
Dimensions are for reference only.
ORDERING INFORMATION
Control Relays – Series GP Power Relays
SPECIFICATIONS ( Cont.)
Coil Operating Voltage
Contact Ratings
Model Series
GP - Power
ML - Magnetic
GP
Latch Relay
Voltage
540 VAC
380 VAC
380 VAC
380 VAC
220 VAC
220 VAC
220 VAC
220 VAC
220 VAC
220 VAC
220 VAC
220 VAC
220 VAC
120 VDC
48 VDC
48 VDC
Nominal Coil Voltage
Minimum Pick-up voltage
at 40°C
Maximum voltage for
continuous use
For 380 Volts AC – Use 6800 ohms 4 watt resistor in series with 220 volts AC relay
For 440 Volts AC – Use 8200 ohms 6 watt resistor in series with 220 volts AC relay
Coil drop-out voltage is between 10% and 40% of the rated operating voltages for both DC and AC (For example: in a 120 VAC unit, drop-
out will occur between 12 and 48 volts.) DC relays will function with unfiltered DC from a full-wave bridge rectifier.
Coil Voltage
A - 12 VDC
B - 24 VDC
C - 48 VDC
D - 125 VDC
F - 250 VDC*
G - 24 VAC 60Hz
I - 120 VAC 60Hz
J - 220 VAC 60Hz
Current
(Amps)
3 x 3.3
3 x 6
1.25
A
2.5
1.5
1.5
15
10
20
15
10
10
3
5
5
2
DC
12
9.5
13.5
Options
N - Magnetic Blow-out Device
Q - Light to indicate coil energization (with 120
R - Internal diode to suppress coil de-energization
Time Constant
VAC, 125 VDC, 220VAC, 250 VDC voltages
only) – GP series only
transient (When used on DC unit, relay release
time increases to the same value as the AC
equivalent.) – GP series only
Power Factor
COS Ø = 0.25
COS Ø = 0.5
COS Ø = 0.8
COS Ø = 0.5
COS Ø = 0.8
N
Resistive
Resistive
Resistive
Resistive
Resistive
Resistive
Resistive
Resistive
Resistive
24
19
27
5 ms
or
48
38
53
Socket Available
See Page 5
125
100
143
49
250
200
275
15 000 000
30 000 000
20 000 000
18 000 000
Operations
Number of
1 500 000
3 000 000
2 000 000
1 000 000
Electrical
200 000
200 000
400 000
200 000
15 000
10 000
20 000
20 000
2 contacts in parallel
2 contacts in parallel
2 contacts in parallel
with blow-out device
2 contacts in series
50/60Hz
24
20
27
Filament lamps
3hp motor
3hp motor
Remarks
120
102
137
Technical Support Center 1-800-522-6752
220
188
245
www.tycoelectronics.com
Electronics