9-1393792-3 TE Connectivity, 9-1393792-3 Datasheet - Page 356

no-image

9-1393792-3

Manufacturer Part Number
9-1393792-3
Description
Electromechanical Relay DPDT 3A 5VDC 125Ohm Through Hole
Manufacturer
TE Connectivity
Type
Signal Relayr
Datasheet

Specifications of 9-1393792-3

Contact Arrangement
DPDT
Dc Coil Voltage
5 V
Coil Current
40 mA
Mounting
Through Hole
1008
Ordering Information
*Standard Coil Voltages: F = 12VDC
Figure 1 – Limiting Curve for Power Load
Figure 2 – Ambient Temperature vs. Coil Voltage for Continuous Duty
Our authorized distributors are more likely to maintain the following items in stock for immediate delivery.
None at present.
Dimensions are shown for
reference purposes only.
Note: See page 1011 for Wiring Diagrams, Suggested PC Board Layouts and Outline Dimensions.
12
10
75
60
50
40
30
20
130
120
110
100
80
70
60
50
40
30
90
0.5
VKP-11 * 42
VKP-15 * 42
VKP-11 * 52
VKP-15 * 52
VKP-31 *42
VKP-35 * 42
VKP-31 * 52
VKP-35 * 52
90
Part Number
95
1
100
105
Applied Coil Voltage (% of Rated Nominal)
H = 24VDC (Consult factory for availability)
2
110
Switching Current (Amps)
3
115
4
Arrangement
120
1 Form A
1 Form C
1 Form A
1 Form C
1 Form A
1 Form C
1 Form A
1 Form C
Contact
5
Dimensions are in inches over
(millimeters) unless otherwise
specified.
125
7
130
10
135
20
140
30
145
Catalog 1308242
AgNi 0.15
AgNi 0.15
AgNi 0.15
AgNi 0.15
Material
Contact
40
Issued 3-03
AgSnO
AgSnO
AgSnO
AgSnO
150
0 Amp Contact Load
8 Amp Contact Load
16 Amp Contact Load
24 Amp Contact Load
32 Amp Contact Load
40 Amp Contact Load
Specifications and availability
subject to change.
Safe breaking, arc extinguished (normally open contact) for resistive loads.
Immersion Cleanable Case
Immersion Cleanable Case
Immersion Cleanable Case
Immersion Cleanable Case
Enclosure
Open
Open
Open
Open
Assumptions:
10. Subtract 10°C from the maximum allowable
1. Thermal resistance = 40°C per watt.
2. Still air.
3. Nominal coil resistance.
4. Maximum mean coil temperature = 180°C.
5. Coil temperature rise due to load.
6. Thermal resistance and power dissipation
7 . Curves are based on 1.6 watts at 23°C.
8. When full lifetime is at high ambient and high
9. Data is for open relays.
based on coil resistance at 180°C.
load current, subtract 25°C from maximum
allowable ambient temperature.
ambient temperature for sealed version.
= 3.5°C @ 8 amps.
= 10°C @ 16 amps.
= 20°C @ 24 amps.
= 36°C @ 32 amps.
= 55°C @ 40 amps.
TYCO ELECTRONICS
Termination Footprint
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
U.S.A.
U.S.A.
U.S.A.
U.S.A.
U.S.A.
U.S.A.
U.S.A.
U.S.A.

Related parts for 9-1393792-3