Specifications of 104068-5

Pitch
1.27 mm
Number Of Rows
2
Number Of Contacts
50
Gender
HDR
Contact Plating
Gold Over Nickel
Termination Method
Solder
Peak Reflow Compatible (260 C)
No
Terminal Type
Straight PCB Thru Hole
Connector Shroud
Yes
Body Material
Thermoplastic
Leaded Process Compatible
No
Rohs Compliant
No
Connector Type
Header
Shrouded
Yes
Mount Angle
Vertical
Pcb Mount Style
Through Hole
Pcb Mount Retention
Without
Voltage (vac)
30
Insulation Resistance (m?)
5,000
Dielectric Withstanding Voltage (v)
500
Termination Post Length (mm [in])
2.54 [0.100]
Solder Tail Contact Plating
Tin-Lead
Number Of Positions
50
Contact Base Material
Phosphor Bronze
Contact Plating, Mating Area, Material
Gold (30)
Connector Style
Plug
Housing Material
Thermoplastic - GF
Ul Flammability Rating
UL 94V-0
Housing Color
Black
Rohs/elv Compliance
ELV compliant, 5 of 6 Compliant
Lead Free Solder Processes
Wave solder capable to 240°C, Wave solder capable to 260°C, Wave solder capable to 265°C, Reflow solder capable to 245°C, Reflow solder capable to 260°C, Pin-in-Paste capable to 245°C, Pin-in-Paste capable to 260°C
Approved Standards
UL E28476, CSA LR7189
Temperature Range (°c)
-65 – +105
Packaging Method
Tube
4.
4.1.
4.2.
4.3.
4.4.
Rev C
QUALITY ASSURANCE PROVISIONS
Qualification Testing
A.
B.
Requalification Testing
If changes significantly affecting form, fit or function are made to the product or manufacturing process,
product assurance shall coordinate requalification testing, consisting of all or part of the original testing
sequence as determined by development/product, quality and reliability engineering.
Acceptance
Acceptance is based on verification that the product meets the requirements of Figure 1. Failures
attributed to equipment, test setup or operator deficiencies shall not disqualify the product. When
product failure occurs, corrective action shall be taken and specimens resubmitted for qualification.
Testing to confirm corrective action is required before resubmittal.
Quality Conformance Inspection
The applicable quality inspection plan will specify the sampling acceptable quality level to be used.
Dimensional and functional requirements shall be in accordance with the applicable product drawing
and this specification.
Specimen Selection
Specimens shall be prepared in accordance with applicable Instruction Sheets and shall be
selected at random from current production. All test groups shall consist of a minimum of 5
specimens.
Test Sequence
Qualification inspection shall be verified by testing specimens as specified in Figure 2.