CLP-212S Aavid Thermalloy, CLP-212S Datasheet - Page 36

no-image

CLP-212S

Manufacturer Part Number
CLP-212S
Description
CLIP
Manufacturer
Aavid Thermalloy
Datasheet

Specifications of CLP-212S

Accessory Type
Clip(s)
Product
Hardware & Accessories
Dimensions
10 mm L x 7 mm W x 5.7 mm H
Designed For
Sensor Thin Components
For Use With/related Products
Heat Sinks
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
032622
CLP212S
36
1.
1.1
2.
2.1
2.2
2.3
2.4
2.5
3.
3.1
3.1.1
3.1.2
3.1.3
3.1.4
3.1.5
3.2
3.2.1
3.2.2
3.2.3
3.2.4
3.2.5
4.
4.1
5.
5.1
6.
6.1
7.
7.1
8.
8.1
8.2
8.3
8.4
8.5
9.
9.1
Provided by PENNY + GILES • Test Certificate No. 3318
www.aavidthermalloy.com
Shock and Vibration Testing
TEST CONDUCTED
Sine Vibration and 1/2 Sine Shock
SPECIMEN DATA
No. Off:
Identification:
Reference No.(s):
Serial No.(s):
Condition received:
SPECIFICATIONS AND/OR NATIONAL STANDARDS
Equipment Specification
Authority:
Title:
Issue:
Data:
Requirements:
RELATED NATIONAL STANDARD
Authority:
Title:
Issue:
Data:
Requirement(s):
CLIENT
El.Bo.Mec Thermalloy - Via Del Tipografo, 4 - 40138 Bologna, Italy
RECEIPT OF TEST SPECIMEN
Specimen received 28.05.98 under request to test form No. 3318, dated 28.05.98.
DATE OF TEST
Test commenced and completed 01.06.98.
DISPOSAL OF TEST SPECIMEN
Specimen returned to client under delivery note 1362 dated 02.06.98.
TEST METHOD/PROCEDURE
The heat sink assembly was mounted onto the shaker table and subjected to a sinusoidal vibration test as follows:
Frequency Range:
Vibration Amplitude:
Rate of Change of Frequency:
Test Duration:
During the above 20 minute period the heat sink assembly was observed visually
for evidence of the max mounts becoming detached.
The procedures described in 8.1 and 8.2 above were repeated such that vibration test
was conducted in all three mutually perpendicular axes.
The heat sink assembly was then subjected to a shock test as follows:
Shock Pulse Envelope:
Period:
Amplitude:
Number of Shocks:
Application:
During the above 20 minute period the heat sink assembly was observed visually
for evidence of the max mounts becoming detached.
TEST RESULTS
The max clips did not break free from the heat sink assembly. No physical degradation was observed.
AMERICA
EUROPE
As date
N/A
N/A
N/A
N/A
N/A
BSI
BS2011
Test Ea: 1988, Test Fc: 1983.
Tests Ea and Fc, as modified by Request To Test form 3318
Italy Tel: +39 051 764011 email: sales.it@aavid.com
United Kingdom Tel: +44 1793 401400 email: sales.uk@aavid.com
4 off
Heat sink S509/40 with MAX Clips retaining 4 off semiconductors
MAX 01, MAX 02, MAX 03, MAX 04
1, 2, 3, and 4
OK
8 Hz to 100 Hz
± 3g pk
1 Octave per minute
20 minutes
112 sine
6 ms
5 g
3
3 shocks per sense per axis
USA Tel: +1 (603) 224-9988 email: info@aavid.com
ASIA
Singapore Tel: +65 6362 8388 email: sales@aavid.com.sg
Taiwan Tel: +886(2) 2698-9888 email: sales@aavid.com.tw

Related parts for CLP-212S