PEF81902FV1.1 Lantiq, PEF81902FV1.1 Datasheet - Page 194

no-image

PEF81902FV1.1

Manufacturer Part Number
PEF81902FV1.1
Description
Manufacturer
Lantiq
Datasheet

Specifications of PEF81902FV1.1

Lead Free Status / RoHS Status
Supplier Unconfirmed
EN_B1R
EN_B2X
EN_B1X
D_CS
4.7.5
HCI_CR
Value after reset: 04
DPS_CI1 Data Port Selection CI1 Handler
Data Sheet
DPS_CI1 EN_CI1
7
1 =
Enable Transceiver B1 Receive Data (transmitter receives from IOM)
0 =
1 =
Enable Transceiver B2 Transmit Data (transmitter transmits to IOM)
0 =
1 =
Enable Transceiver B1 Transmit Data (transmitter transmits to IOM)
0 =
1 =
These bits are used to individually enable/disable the D-channel and the
receive/transmit paths for the B-channels for the S-transceiver.
D Channel Selection
This bit is used to select the IOM channel to which the S-transceiver D-
channel is related to.
0 =
1 =
HCI_CR - Control Register for HDLC and CI1 Data
0 =
1 =
The corresponding data path to the transceiver is enabled.
The corresponding data path to the transceiver is disabled
The corresponding data path to the transceiver is enabled.
The corresponding data path to the transceiver is disabled
The corresponding data path to the transceiver is enabled.
The corresponding data path to the transceiver is disabled
The corresponding data path to the transceiver is enabled.
D-channel in IOM-channel 0
D-channel in IOM-channel 1
The CI1 data is output on DD and input from DU
The CI1 data is output on DU and input from DD
H
EN_D
EN_B2H EN_B1H DPS_H
read/write
180
Register Description
Address:
HCS
PEF 81902
2001-11-12
0
52
H

Related parts for PEF81902FV1.1