Specifications of 5962-8950304CA

Lead Free Status / RoHS Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
5962-8950304CA
Manufacturer:
INTERS
Quantity:
238
DSCC FORM 2234
APR 97
(original equipment), design applications, and logistics purposes.
prepared specification or drawing.
the individual documents. This coordination will be accomplished using DD Form 1692, Engineering Change Proposal.
configuration control and the applicable SMD to that system. DLA Land and Maritime will maintain a record of users and this
list will be used for coordination and distribution of changes to the drawings. Users of drawings covering microelectronics
devices (FSC 5962) should contact DLA Land and Maritime -VA, telephone (614) 692-0547.
43218-3990, or telephone (614) 692-0540.
accepted by DLA Land and Maritime -VA.
MIL-HDBK-103 have agreed to this drawing and a certificate of compliance (see 3.6 herein) has been submitted to and
5. PACKAGING
5.1 Packaging requirements. The requirements for packaging shall be in accordance with MIL-PRF-38535, appendix A.
6. NOTES
6.1 Intended use. Microcircuits conforming to this drawing are intended for use for Government microcircuit applications
6.2 Replaceability. Microcircuits covered by this drawing will replace the same generic device covered by a contractor-
6.3 Configuration control of SMD's. All proposed changes to existing SMD's will be coordinated with the users of record for
6.4 Record of users. Military and industrial users shall inform DLA Land and Maritime when a system application requires
6.5 Comments. Comments on this drawing should be directed to DLA Land and Maritime -VA, Columbus, Ohio
6.6 Approved sources of supply. Approved sources of supply are listed in MIL-HDBK-103. The vendors listed in
MICROCIRCUIT DRAWING
COLUMBUS, OHIO 43218-3990
DLA LAND AND MARITIME
STANDARD
* PDA applies to subgroup 1.
Interim electrical parameters
Final electrical test parameters
Group A test requirements
Groups C and D end-point
MIL-STD-883 test requirements
(method 5004)
(method 5004)
(method 5005)
electrical parameters
(method 5005)
TABLE II. Electrical test requirements.
1*,2,3,9
1,2,3,9,10,11
1
MIL-STD-883, method 5005,
SIZE
A
(in accordance with
Subgroups
table I)
---
REVISION LEVEL
J
SHEET
5962-89503
15