MC34911G5ACR2 Freescale, MC34911G5ACR2 Datasheet - Page 57

MC34911G5ACR2

Manufacturer Part Number
MC34911G5ACR2
Description
Manufacturer
Freescale
Datasheet

Specifications of MC34911G5ACR2

Turn Off Delay Time
10us
Number Of Drivers
2
Operating Temperature (min)
-40C
Lead Free Status / RoHS Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MC34911G5ACR2
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Table 35. Static Electrical Characteristics (continued)
34911, unless otherwise noted. Typical values noted reflect the approximate parameter mean at T
conditions, unless otherwise noted.
57
33911
HIGH SIDE OUTPUT HS1 PIN (HS1)
LOW SIDE OUTPUTS LS1 AND LS2 PINS (LS1, LS2)
ELECTRICAL CHARACTERISTICS
STATIC ELECTRICAL CHARACTERISTICS
100.
101.
102.
103.
104.
Output Drain-to-Source On resistance
Output Current Limitation
Open Load Current Detection
Leakage Current
Short-circuit Detection Threshold
Over-temperature Shutdown
Over-temperature Shutdown Hysteresis
Output Drain-to-Source On resistance
Output Current Limitation
Open Load Current Detection
Leakage Current
Active Output Energy Clamp
Short-circuit Detection Threshold
Over-temperature Shutdown
Over-temperature Shutdown Hysteresis
Notes
95.
96.
97.
98.
99.
Characteristics noted under conditions 5.5 V ≤ V
T
T
T
0 V < V
-0.2 V < V
5.5 V < V
T
T
T
2.0 V < V
-0.2 V < V
I
5.5 V < V
OUT
J
J
J
J
J
J
= 25°C, I
= 150°C, I
= 150°C, I
= 25°C, I
= 125°C, I
= 125°C, I
This parameter is production tested up to T
When over-current occurs, the High Side stays ON with limited current capability and the HS1CL flag is set in the HSSR
When open Load occurs, the flag (HS1OP) is set in the HSSR
When short-circuit occurs and if the HVSE flag is enabled, HS1 automatically shut down.
When over-temperature Shutdown occurs, the High Side is turned off. All flags in HSSR are set.
When over-current occurs, the corresponding Low Side stays ON with limited current capability and the LSxCL flag is set in the LSSR
When open load occurs, the flag (LSxOP) is set in the LSSR.
When short-circuit occurs and if the HVSE flag is enabled, both LS automatically shut down.
When over-temperature shutdown occurs, both Low Sides are turned off. All flags in LSSR are set.
Guaranteed by characterization but not production tested
= 150 mA
OUT
SUP
OUT
SUP
HS1
OUT
LOAD
LOAD
< V
LOAD
LOAD
LOAD
LOAD
< 27 V
< V
< 27 V
< V
< VS1
SUP
= 50 mA; V
= 150 mA, V
SUP
S2
= 50 mA; V
= 30 mA; 5.5 V < V
= 150 mA, V
= 120 mA, 5.5 V < V
- 2.0 V
+ 0.2 V
(96)
(100)
Characteristic
(99),
(103),
(97)
(101)
SUP
(104)
SUP
(98)
SUP
(102)
(104)
SUP
> 9.0 V
> 9.0 V
> 9.0 V
> 9.0 V
(104)
(104)
SUP
SUP
(95)
< 9.0 V
< 9.0 V
A
= 125°C and guaranteed by process monitoring up to T
(95)
SUP
≤ 18 V, -40°C ≤ T
.
T
T
HSSD_HYS
Symbol
R
R
LSSD_HYS
V
I
I
I
V
T
I
V
LIMHS1
T
LIMLSX
A
OLHS1
I
OLLSX
I
DS(ON)
DS(ON)
CLAMP
LEAK
LEAK
THSC
HSSD
THSC
LSSD
≤ 125°C for the 33911 and -40°C ≤ T
V
V
SUP
SUP
Min
150
160
150
2.0
60
Analog Integrated Circuit Device Data
+2
-2
J
= 150°C.
A
Typ
120
165
275
165
5.0
8.0
10
10
= 25°C under nominal
Freescale Semiconductor
V
SUP
Max
250
180
350
180
7.0
7.5
2.5
4.5
10
14
10
10
12
10
A
≤ 85°C for the
+5
.
Unit
mA
mA
mA
mA
µA
µA
°C
°C
°C
°C
Ω
Ω
V
V
V
.

Related parts for MC34911G5ACR2