SPECIFICATIONS
Contact
Coil
#1 This value can change due to the switching frequency, environmental conditions,
Remarks
*
*
*
*
*
*
*
*
*
TYPICAL APPLICATIONS
• Power windows
• Auto door lock
• Electrically powered sunroof
• Electrically powered mirror, etc.
1
2
3
4
5
6
7
8
9
Arrangement
Contact material
Initial contact resistance (Initial)
(By voltage drop 6 V DC 1A)
Contact voltage drop
Rating
Expected life
(min. operations)
Nominal operating power
Compliance with RoHS Directive
and desired reliability level, therefore it is recommended to check this with the
actual load.
At nominal switching capacity, operating frequency: 1s ON, 9s OFF
N.O.: at 5 A (steady), 25 A (inrush)/N.C.: at 20 A (brake) 14 V DC, operating
frequency: 0.5s ON, 9.5s OFF
At 20A 14 V DC (Motor lock), operating frequency: 0.5s ON, 9.5s OFF
Measurement at same location as “Initial breakdown voltage” section
Detection current: 10mA
Excluding contact bounce time
Half-wave pulse of sine wave: 11ms; detection: 10 s
Half-wave pulse of sine wave: 6ms
Detection time: 10 s
24.6
.969
Nominal switching
capacity
Max. carrying current
Min. switching capacity
Mechanical (at 120 cpm)
Electrical
17.0
.669
Resistive load
Motor load
18.5
.728
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
mm
inch
#1
Ag alloy (Cadmium free)
(12 V, at 85
Max. 0.2V (at 10 A)
N.O.: 20 A 14 V DC
N.C.: 10 A 14 V DC
(12 V, at 20
35 A for 2 minutes,
30 A for 2 minutes,
Typ. 6 m
Typ. 9 m
FEATURES
• Silent
Noise has been reduced by
approximately 20 dB, using our own
silencing design.
• Twin (1 Form C
Forward/reverse motor control is possible
with a single relay.
• Sealed construction
• Simple footprint enable ease of PC
25 A for 1 hour
20 A for 1 hour
1 Form C
1 A 12 V DC
Min. 2 10
Min. 10
Min. 10
Min. 10
640 mW
TWIN POWER SILENT
AUTOMOTIVE RELAY
C185
(N.O.)
(N.C.)
C68
5
5
*
*
7
5
1
3
*
2
2
F)
F)
2)
Characteristics
*
*
ORDERING INFORMATION
Standard packing: Carton(tube package) 32pcs. Case: 800pcs.
Max. operating speed
(at nominal switching capacity)
Initial insulation resistance*
Initial breakdown
voltage*
Operate time*
(at nominal voltage)(at 20
Release time*
(at nominal voltage)(at 20
Shock resistance
Vibration resistance
Conditions for
operation, transport
and storage*
(Not freezing and
condensing at low
temperature)
Mass
10
11
Time of vibration for each direction;
Refer to Conditions for operation, transport and storage mentioned in AMBIENT
ENVIRONMENT.
Please inquire if you will be using the relay in a high temperature atmosphere
(110 C
X
Contact arrangement
5
230
Y
1 Form C
Z
11
F).
6
X, Y, direction: 2 hours
Z direction: 4 hours
6
Ex. CR
Between open
contacts
Between contacts
and coil
Functional*
Destructive*
Functional*
Destructive*
Ambient
temperature
Humidity
2
board layout
Discontinued as of August 31, 2010
C68
C68
CR RELAYS
4
Coil
Normally
Open
2
F)
F)
7
9
8
10
–
Min. 100 M
Common
Coil voltage(DC)
12 V
Min. 1,000 m/s
Min. 44.1 m/s
Min. 44.1 m/s
5% R.H. to 85% R.H.
Approx.
Min. 100 m/s
500 Vrms for 1 min.
500 Vrms for 1 min.
Max. 10 ms (initial)
Max. 10 ms (initial)
10 Hz to 100 Hz,
10 Hz to 500 Hz,
–40 F to +185 F
–40 C to +85 C
12 V
6 cpm
12.5g.44 oz
(at 500 V DC)
2
2
2
Normally
Closed
2
{10G}
{4.5G}
{4.5G}
{100G}
CR
Coil