5962-8961403MXA E2V, 5962-8961403MXA Datasheet - Page 15

no-image

5962-8961403MXA

Manufacturer Part Number
5962-8961403MXA
Description
Manufacturer
E2V
Datasheet

Specifications of 5962-8961403MXA

Lead Free Status / RoHS Status
Supplier Unconfirmed

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
5962-8961403MXA
Quantity:
871
DSCC FORM 2234
APR 97
assured (see 3.6 herein).
4.4.4 Group E inspection. Group E inspection is required only for parts intended to be marked as radiation hardness
a.
b.
c.
DEFENSE SUPPLY CENTER COLUMBUS
End-point electrical parameters shall be as specified in table IIA herein.
For device classes Q and V, the devices or test vehicle shall be subjected to radiation hardness assured tests as
specified in MIL-PRF-38535 for the RHA level being tested. For device class M, the devices shall be subjected to
radiation hardness assured tests as specified in MIL-PRF-38535, appendix A for the RHA level being tested. All
device classes must meet the postirradiation end-point electrical parameter limits as defined in table I at
T
When specified in the purchase order or contract, a copy of the RHA delta limits shall be supplied.
A
Line
1/ Blank spaces indicate tests are not applicable.
2/ Any or all subgroups may be combined when using high-speed testers.
3/ Subgroups 7 and 8 functional tests shall verify the truth table.
4/ * indicates PDA applies to subgroup 1 and 7.
5/ ** see 4.4.1e.
6/
7/ See 4.4.1d.
no.
= +25 C 5 C, after exposure, to the subgroups specified in table IIA herein.
10
MICROCIRCUIT DRAWING
1
2
3
4
5
6
7
8
9
COLUMBUS, OHIO 43216-5000
with reference to the previous interim electrical parameters (see line 1).
indicates delta limit (see table IIB) shall be required where specified, and the delta values shall be computed
Interim electrical
Static burn-in
Same as line 1
Dynamic burn-in
Same as line 1
Final electrical
Group A test
requirements (see 4.4)
Group C end-point
Group D end-point
Group E end-point
(method 1015)
parameters (see 4.2)
(method 1015)
parameters (see 4.2)
electrical
parameters (see 4.4)
electrical
parameters (see 4.4)
electrical
parameters (see 4.4)
STANDARD
Test requirements
TABLE IIA. Electrical test requirements. 1/ 2/ 3/ 4/ 5/ 6/ 7/
(in accordance with
TM 5005, table I)
8A, 8B, 9, 10, 11
1*, 2, 3, 7*, 8A,
MIL-STD-883,
1, 2, 3, 4**, 7,
8B, 9, 10, 11
Subgroups
Required
2, 8A, 10
2, 8A, 10
required
class M
Device
1, 7, 9
Not
SIZE
A
8A, 8B, 9, 10, 11
1*, 2, 3, 7*, 8A,
1, 2, 3, 4**, 7,
8B, 9, 10, 11
2, 3, 8A, 8B
Required
required
class Q
2, 3, 7,
Device
8A, 8B
1, 7, 9
Not
REVISION LEVEL
MIL-PRF-38535, table III)
(in accordance with
F
Subgroups
8A, 8B, 9, 10, 11
1*, 2, 3, 7*, 8A,
8B, 9, 10, 11
1, 2, 3, 4**, 7,
1, 2, 3, 7, 8A,
8B, 9, 10, 11
2, 3, 8A, 8B
SHEET
Required
required
1*, 7*
1*, 7*
class V
Device
1, 7, 9
1, 7, 9
Not
5962-89614
15