GP2D12 Sharp Electronics, GP2D12 Datasheet - Page 3

no-image

GP2D12

Manufacturer Part Number
GP2D12
Description
Manufacturer
Sharp Electronics
Type
Sensor DIST. Measurer
Datasheet

Specifications of GP2D12

Sensing Distance
80cm
Operating Temperature (max)
60C
Operating Temperature (min)
-10C
Pin Count
3
Operating Temperature Classification
Commercial
Lead Free Status / RoHS Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
GP2D12
Manufacturer:
SHARP
Quantity:
26 000
Part Number:
GP2D12 /GP2Y0A21
Manufacturer:
Texas
Quantity:
20
Part Number:
GP2D120
Manufacturer:
SHARP
Quantity:
4 728
Part Number:
GP2D120/J
Manufacturer:
SHARP
Quantity:
1 000
Part Number:
GP2D120C
Manufacturer:
SHARP
Quantity:
18 803
RELIABILITY
listed in Table 1.
NOTES:
1. Test conditions are according to Electro-optical Characteristics, shown on page 2.
2. At completion of the test, allow device to remain at nominal room temperature and humidity (non-condensing) for two hours.
3. Confidence level: 90%, Lot Tolerance Percent Defect (LTPD): 20% / 40%.
MANUFACTURER’S INSPECTION
Inspection Lot
Inspection Method
based on ISO 2859 shall be adopted.
NOTE: *Any one of these that affects the Electro-optical Characteristics shall be considered a defect.
Temperature Cycling
High Temperature and
High Humidity Storage
High Temperature Storage
Low Temperature Storage
Operational Life
(High Temperature)
Mechanical Shock
Variable Frequency Vibration
Major Defect
Minor Defect
The reliability of requirements of this device are
Inspection shall be carried out per each delivery lot.
A single sampling plan, normal inspection level II
DEFECT
TEST ITEMS
Electro-optical characteristics defect
Defect to appearance or dimensions (crack, split, chip, scratch, stain)*
One cycle -40°C (30 min.) to +70°C in 30
minutes, repeated 25 times
+40°C, 90% RH, 500h
+70°C, 500h
-40°C, 500h
+60°C, V
100 m / s
3 times / ±X, ±Y, ±Z direction
10-to-55-to-10 Hz i n 1 minute
Amplitude: 1.5 mm
2 h i n e a c h X, Y, Z direction
2
INSPECTION ITEM and TEST METHOD
CC
, 6.0 ms
TEST CONDITIONS
= 5 V, 500h
Table 2. Quality Level
Table 1. Reliability
3
Initial × 0.8 > V
V
JUDGEMENT
O
CRITERIA
FAILURE
> Initial × 1.2
O
DEFECTIVE (C)
SAMPLES (n),
n = 11, C = 0
n = 11, C = 0
n = 11, C = 0
n = 11, C = 0
n = 11, C = 0
n = 6, C = 0
n = 6, C = 0
AQL (%)
0.4
1.0
Data Sheet
GP2D12

Related parts for GP2D12