MC35XS3400CPNA Freescale, MC35XS3400CPNA Datasheet - Page 23

no-image

MC35XS3400CPNA

Manufacturer Part Number
MC35XS3400CPNA
Description
Manufacturer
Freescale
Datasheet

Specifications of MC35XS3400CPNA

Switch Type
High Side
Power Switch Family
MC35XS3400
Input Voltage
4 to 28V
Power Switch On Resistance
170mOhm
Output Current
6A
Number Of Outputs
4
Mounting
Surface Mount
Supply Current
6.5mA
Package Type
PQFN
Operating Temperature (min)
-40C
Operating Temperature Classification
Automotive
Pin Count
24
Lead Free Status / RoHS Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MC35XS3400CPNA
Manufacturer:
FREESCALE
Quantity:
20 000
Fail-safe and Fault.
contained in succeeding paragraphs.
depending on IN[x] input.
the following signals:
SLEEP MODE
Analog Integrated Circuit Device Data
Freescale Semiconductor
IN_ON[x]
IN[x]
The 35XS3400 has four operating modes: Sleep, Normal,
The
The 35XS3400 transits to operating modes according to
• wake-up =
• fail = (V
• fault = OC[0:3] or OT[0:3] or SC[0:3] or UV
The 35XS3400 is in Sleep mode when:
• V
• wake-up = 0,
• fail = X,
• fault = X.
IN_ON[2] or IN_ON[3],
time-out and FSI input not shorted to ground ),
( UV ) or ( OV and OV_dis ).
PWR
Figure 10
and V
Figure 10. IN_ON[x] internal signal
Fail-Safe
DD
Failure and VDD_FAIL_en) or ( Watchdog
RST
describes an internal signal called IN_ON[x]
DD
Table 6
(wake-up=0)
are within the normal voltage range,
or WAKE or IN_ON[0] or IN_ON[1] or
and
(wake-up=1) and
(fail=1)
and (fault=0)
Figure 11
(fail=1) and
(wake-up=1)
and (fault=1)
summarize details
(fail=0) and (wake-up=1) and (fault=0)
(fail=1) and (wake-up=1) and (fault=0)
(fail=1)
(wake-up=1)
and (fault=0)
t
IN
(wake-up=0)
Figure 11. Operating Modes
OPERATIONAL MODES
and
Fault
Sleep
battery voltage (VPWR) prior to any I/O transitions. This is
also the state of the device when the WAKE and
IN_ON[0:3] are logic [0]. In the Sleep mode, the output and
all unused internal circuitry, such as the internal regulator, are
off to minimize draw current. In addition, all SPI-configurable
features of the device are as if set to logic [0].
Table 6. 35XS3400 Operating Modes
Fail-safe
Normal
x = Don’t care.
(wake-up=1)
and (fault=1)
Mode
Sleep
Fault
This is the Default mode of the device after first applying
wake-up
(fail=0)
(wake-up=1)
and (fault=1)
(fail=0)
(wake-up=1)
and (fault=0)
0
1
1
1
(fail=0) and (wake-up=1) and (fault=0)
(wake-up=0)
fail fault
and
0
1
X
x
and
0
0
1
FUNCTIONAL DEVICE OPERATION
x
Normal
Device is in Sleep mode. All
outputs are OFF.
Device is currently in Normal
mode. Watchdog is active if
enabled.
Device is currently in Fail-safe
mode due to watchdog timeout
or V
output states depend on the
corresponding input in case
FSI is open.
Device is currently in Fault
mode. The faulted output(s) is
(are) OFF. The safe autoretry
circuitry is active to turn-on
again the output(s).
DD
OPERATIONAL MODES
Failure conditions. The
Comments
RST
35XS3400
and
23

Related parts for MC35XS3400CPNA