MC33988CPNA Freescale, MC33988CPNA Datasheet - Page 20

no-image

MC33988CPNA

Manufacturer Part Number
MC33988CPNA
Description
Manufacturer
Freescale
Datasheet

Specifications of MC33988CPNA

Switch Type
High Side
Power Switch Family
MC33988
Power Switch On Resistance
16mOhm
Output Current
30A
Number Of Outputs
Dual
Mounting
Surface Mount
Supply Current
20mA
Package Type
Power QFN EP
Operating Temperature (min)
-40C
Operating Temperature Classification
Automotive
Pin Count
16
Lead Free Status / RoHS Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MC33988CPNA
Manufacturer:
FREESCALE
Quantity:
414
Part Number:
MC33988CPNA
Manufacturer:
FREESCALE
Quantity:
414
FAULT MODE
driving the
OVER-TEMPERATURE FAULT (NON-LATCHING)
shutdown circuitry in each output structure. Over-
temperature detection is enabled when an output is in the ON
state.
results in the faulted output turning OFF until the temperature
falls below the T
until action is taken by the MCU to shut OFF the output, or
until the offending load is removed.
in the status register and cleared after either a valid SPI read
or a power reset of the device.
OVER-VOLTAGE FAULT (NON-LATCHING)
fault (OVF) condition on the V
the OFF state until the over-voltage condition is removed.
When experiencing this fault, the OVF fault bit is set in the bit
OD1 and cleared after either a valid SPI read or a power reset
of the device.
disabled trough SPI (bit OV_dis).
UNDER-VOLTAGE SHUTDOWN (LATCHING OR
NON-LATCHING)
6.0 V. As long as the V
specified range, the internal logic states within the device will
be sustained.
under-voltage threshold (VPWRUV) output will turn off, FS
will go to Logic [0], and the fault register UVF bit will be set to
1. Two cases need to be considered when the battery level
recovers:
SPI (bit UV_dis = 1). In this case, the FS and UVF bit do not
20
33988
FUNCTIONAL DEVICE OPERATION
PROTECTION AND DIAGNOSIS FEATURES
The 33988 indicates the following faults as they occur by
• Over-temperature fault
• Open load fault
• Over-current fault (high and low)
• Over-voltage and under-voltage fault
The 33988 incorporates over-temperature detection and
For the output, an over-temperature fault (OTF) condition
When experiencing this fault, the OTF fault bit will be set
The 33988 shuts down the output during an over-voltage
The over-voltage protection and diagnostic can be
The output(s) will latch off at some battery voltage below
In the case where the battery voltage drops below the
• If output(s) command is (are) low, FS will go to Logic [1]
• If the output command is ON, then FS will remain at
The under-voltage protection can be disabled through the
but the UVF bit will remain set to 1 until the next read
operation.
Logic [0]. The output must be turned OFF and ON again
to re-enable the state of output and release FS . The
UVF bit will remain set to 1 until the next read operation.
FS
pin to Logic [0]:
SD(HYS)
. This cycle will continue indefinitely
DD
level stays within the normal
PWR
pin. The output remains in
PROTECTION AND DIAGNOSIS FEATURES
fault condition is removed, except for over-current and in
some cases under-voltage.
available (and reset) via the SO pin during the first valid SPI
communication (refer to
report any under-voltage fault condition and the output state
will not be changed as long as the battery voltage does not
drop any lower than 2.5V.
OPEN LOAD FAULT (NON-LATCHING)
each output. Output open load fault (OLF) is detected and
reported as a fault condition when that output is disabled
(OFF). The open load fault is detected and latched into the
status register after the internal gate voltage is pulled low
enough to turn OFF the output. The OLF fault bit is set in the
status register. If the open load fault is removed, the status
register will be cleared after reading the register.
OL_dis).
detection circuitry (OL_dis bit sets to logic [1]) in case
of permanent open load fault condition.
OVER-CURRENT FAULT (LATCHING)
detection levels (I
high detection levels (I
The two selectable, simultaneously active over-current
detection levels, defined by I
Figure
(I
current low detect level and the over-current condition
exceeds the programmed over-current time period (t
device will latch the effected output OFF.
then the device will immediately latch the fault and turn OFF
the output, regardless of the selected t
until the device is commanded OFF and then ON again.
REVERSE BATTERY
low as -16V. Under these conditions, the output’s gates are
enhanced to keep the junction temperature less than 150°C.
The ON resistance of the output is fairly similar to that in the
Normal mode. No additional passive components are
required.
OCL0
The
Fault information is retained in the fault register and is
The 33988 incorporates open load detection circuitry on
The open load protection can be disabled trough SPI (bit
The device has eight programmable over-current low
If the load current level ever reaches the selected over-
If at any time the current reaches the selected I
For both cases, the device output will stay off indefinitely
The output survives the application of reverse voltage as
: I
6. The eight different over-current low detect levels
FS
OCL7
It is recommended to disable the open load
pin will automatically return to Logic [1] when the
) are likewise illustrated in
OCL
) and two programmable over-current
OCH
Analog Integrated Circuit Device Data
Table
) for maximum device protection.
OCH
16).
and I
Freescale Semiconductor
OCL
OCL
Figure
, are illustrated in
driver.
6.
OCH
OCx
level,
), the

Related parts for MC33988CPNA