5962-8867005LA E2V, 5962-8867005LA Datasheet - Page 11

no-image

5962-8867005LA

Manufacturer Part Number
5962-8867005LA
Description
Manufacturer
E2V
Datasheet

Specifications of 5962-8867005LA

Lead Free Status / RoHS Status
Supplier Unconfirmed

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
5962-8867005LA
Manufacturer:
AD
Quantity:
1 150
DSCC FORM 2234
APR 97
(original equipment), design applications, and logistics purposes.
prepared specification or drawing.
the individual documents. This coordination will be accomplished using DD Form 1692, Engineering Change Proposal.
application requires configuration control and the applicable SMD. DSCC will maintain a record of users and this list will be
used for coordination and distribution of changes to the drawings. Users of drawings covering microelectronics devices (FSC
5962) should contact DSCC-VA, telephone (614) 692-0544.
(614) 692-0547.
HDBK-103 have agreed to this drawing and a certificate of compliance (see 3.6 herein) has been submitted to and accepted by
DSCC-VA.
4.3.2 Groups C and D inspections.
4.4 Programming procedures. The programming procedures shall be as specified by the device manufacturer.
5. PACKAGING
5.1 Packaging requirements. The requirements for packaging shall be in accordance with MIL-PRF-38535, appendix A.
6. NOTES
6.1 Intended use. Microcircuits conforming to this drawing are intended for use for Government microcircuit applications
6.2 Replaceability. Microcircuits covered by this drawing will replace the same generic device covered by a contractor-
6.3 Configuration control of SMD's. All proposed changes to existing SMD's will be coordinated with the users of record for
6.4 Record of users. Military and industrial users shall inform Defense Supply Center Columbus (DSCC) when a system
6.5 Comments. Comments on this drawing should be directed to DSCC-VA, Columbus, Ohio 43218-3990, or telephone
6.6 Approved sources of supply. Approved sources of supply are listed in MIL-HDBK-103. The vendors listed in MIL-
a.
b.
c.
(1)
(2)
(3)
End-point electrical parameters shall be as specified in table II herein.
Steady-state life test conditions, method 1005 of MIL-STD-883.
For quality conformance inspection, the programmability sample (see 4.3.1d) shall be included in subgroup 1 test.
DEFENSE SUPPLY CENTER COLUMBUS
Test condition D. The test circuit shall be maintained by the manufacturer under document revision level control
and shall be made available to the preparing or acquiring activity upon request. The test circuit shall specify the
inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified in method
1005 of MIL-STD-883.
T
Test duration: 1,000 hours, except as permitted by method 1005 of MIL-STD-883.
MICROCIRCUIT DRAWING
A
COLUMBUS, OHIO 43218-3990
= +125C, minimum.
STANDARD
SIZE
A
REVISION LEVEL
E
SHEET
5962-88670
11

Related parts for 5962-8867005LA