APPLICATIONS
Direct switching operation:
The IL410, IL4108 isolated switch is mainly suited to control
synchronous motors, valves, relays and solenoids. Fig. 15
shows a basic driving circuit. For resistive load the snubber
circuit R
characteristic.
PACKAGE DIMENSIONS in millimeters
Document Number: 83627
Rev. 1.9, 29-Oct-10
Control
S
21608
C
Fig. 15 - Basic Direct Load Driving Circuit
S
can be omitted due to the high static dV/dt
1
2
3
ZC
IL410
U1
i178014
Option 6
6.30
6.50
10.36
10.16
10.92
9.96
1 min.
7.8
7.4
4° typ.
6
5
4
Crossing, High dV/dt, Low Input Current
0.35
0.25
0.46
0.51
For technical questions, contact:
Optocoupler, Phototriac Output, Zero
R
C
S
S
Inductive load
4
3
8.50
8.70
2
5
220/240
VAC
1.22
1.32
Hot
Nutral
1
6
0.7
2.54 typ.
0.84 typ.
0.84 typ.
Pin one ID
Option 7
7.62 typ.
10.3 max.
8.4 min.
8 min.
3.30
3.81
optocoupleranswers@vishay.com
Indirect switching operation:
The IL410, IL4108 switch acts here as an isolated driver and
thus enables the driving of power thyristors and power triacs
by microprocessors. Fig. 16 shows a basic driving circuit of
inductive load. The resister R1 limits the driving current
pulse which should not exceed the maximum permissible
surge current of the IL410, IL4108. The resister R
only for very sensitive thyristors or triacs from being
triggered by noise or the inhibit current.
Control
3° to 9°
21609
4.6
4.1
1
2
3
0.102
0.249
Fig. 16 - Basic Power Triac Driver Circuit
ISO method A
7.62 to 8.81
7.62 typ.
ZC
IL410
U1
18°
0.20
0.30
Vishay Semiconductors
6
5
4
Option 9
7.62 ref.
10.03
9.53
8 min.
R
330
0.51
1.02
G
R1
360
3.30
3.81
IL410, IL4108
R
C
15° max.
S
S
0.25 typ.
www.vishay.com
Inductive load
18450
G
is needed
220/240
VAC
Hot
Nutral
7

Related parts for IL410-X008T