Specifications of CAT5419WI-25-TE13

Number Of Elements
2
# Of Taps
64
Resistance (max)
2.5KOhm
Power Supply Requirement
Single
Interface Type
Serial (2-Wire/I2C)
Single Supply Voltage (typ)
3.3/5V
Dual Supply Voltage (typ)
Not RequiredV
Single Supply Voltage (min)
2.5V
Single Supply Voltage (max)
6V
Dual Supply Voltage (min)
Not RequiredV
Dual Supply Voltage (max)
Not RequiredV
Operating Temp Range
-40C to 85C
Operating Temperature Classification
Industrial
Mounting
Surface Mount
Pin Count
24
Lead Free Status / RoHS Status
Compliant
WIPER CONTROL AND DATA REGISTERS
Wiper Control Register (WCR)
The CAT5419 contains two 6-bit Wiper Control
Registers, one for each potentiometer. The Wiper
Control Register output is decoded to select one of 64
switches along its resistor array. The contents of the
WCR can be altered in four ways: it may be written by
the host via Write Wiper Control Register instruction; it
may be written by transferring the contents of one of
four associated Data Registers via the XFR Data
Register instruction, it can be modified one step at a
time by the Increment/decrement instruction (see
Instruction section for more details). Finally, it is
loaded with the content of its data register zero (DR0)
upon power-up.
The Wiper Control Register is a volatile register that
loses its contents when the CAT5419 is powered-
down. Although the register is automatically loaded
with the value in DR0 upon power-up, this may be
different from the value present at power-down.
Data Registers (DR)
Each potentiometer has four 6-bit non-volatile Data
Registers. These can be read or written directly by the
host. Data can also be transferred between any of the
Table 3. Instruction Set
2009 SCILLC. All rights reserved.
Characteristics subject to change without notice
Instruction
Read Wiper Control
Register
Write Wiper Control
Register
Read Data Register
Write Data Register
XFR Data Register to
Wiper Control Register
XFR Wiper Control
Register to Data
Register
Gang XFR Data
Registers to Wiper
Control Registers
Gang XFR Wiper
Control Registers to
Data Register
Increment/Decrement
Wiper Control Register
I3
1
1
1
1
1
1
0
1
0
I2
0
0
0
1
1
1
0
0
0
I1
0
1
1
0
0
1
0
0
1
I0
1
0
1
0
1
0
1
0
0
1/0
1/0
1/0
1/0
1/0
1/0
R1
Instruction Set
0
0
0
1/0
1/0
1/0
1/0
1/0
1/0
R0
0
0
0
9
0
0
0
0
0
0
0
0
0
0
four Data Registers and the associated Wiper Control
Register. Any data changes in one of the Data
Registers is a non-volatile operation and will take a
maximum of 5 ms.
If the application does not require storage of multiple
settings for the potentiometer, the Data Registers can
be used as standard memory locations for system
parameters or user preference data.
INSTRUCTIONS
Four of the nine instructions are three bytes in length.
These instructions are:
— Read Wiper Control Register – read the current
— Write Wiper Control Register – change current
— Read Data Register – read the contents of the
— Write Data Register – write a new value to the
wiper position of the selected potentiometer in
the WCR
wiper position in the WCR of the selected
potentiometer
selected Data Register
selected Data Register.
WCR0/ P0
1/0
1/0
1/0
1/0
1/0
1/0
1/0
0
0
Operation
Read the contents of the Wiper Control
Register pointed to by P0
Write new value to the Wiper Control
Register pointed to by P0
Read the contents of the Data Register
pointed to by P0 and R1-R0
Write new value to the Data Register
pointed to by P0 and R1-R0
Transfer the contents of the Data
Register pointed to by P0 and R1-R0 to
its associated Wiper Control Register
Transfer the contents of the Wiper
Control Register pointed to by P0 to the
Data Register pointed to by R1-R0
Transfer the contents of the Data
Registers pointed to by R1-R0 of both
pots to their respective Wiper Control
Registers
Transfer the contents of both Wiper
Control Registers to their respective data
Registers pointed to by R1-R0 of both
four pots
Enable Increment/decrement of the
Control Latch pointed to by P0
Note: 1/0 = data is one or zero
Doc. No. MD-2115 Rev. J
CAT5419

Related parts for CAT5419WI-25-TE13