E5ER-PRQ43F-FLK AC100-240 Omron, E5ER-PRQ43F-FLK AC100-240 Datasheet - Page 2

no-image

E5ER-PRQ43F-FLK AC100-240

Manufacturer Part Number
E5ER-PRQ43F-FLK AC100-240
Description
CONTROLLER DIGITAL 100-240V
Manufacturer
Omron
Series
E5ERr
Type
Digital Controllerr
Datasheet

Specifications of E5ER-PRQ43F-FLK AC100-240

Input Type
Current, Voltage, RTD, Thermocouple (Multiple)
Controller Type
Proportional (PID)
Temperature Range
Selectable, Varies By Input Type
Output Type
Relay + Voltage/Current
Supply Voltage
100 ~ 240VAC
Size
48mm W x 96mm H (1/8 DIN)
Communications
RS-485 (CompoWay/F)
Display Type
LCD; 5 Digit (2), 3 Digit
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Features
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
E5ER-PRQ43F-FLKAC100-240
E5ERPRQ43FFLKAC100240
Ordering Information
■ Digital Controllers
Standard Controllers
Note 1: Specify the power supply specifications when ordering. Model numbers for 100 to 240 VAC are different from those for 24 VAC/VDC.
48 × 96
mm
Size
2. These models are for 100 to 240 VAC only.
3. The auxiliary outputs are transistor outputs.
4. Can be switched between close control and floating control.
Basic control
(1 loop)
2-loop control 2-loop standard control
Position-pro-
portional con-
trol
(1 loop)
Control type
Single-loop standard control
Single-loop heating and cooling control
Single-loop heating and cooling control
Single-loop cascade control
Single-loop control with remote SP
Single-loop proportional control
Single-loop position-proportional control
(See note 4.)
Control mode
2 points: Pulse volt-
age and Pulse volt-
age/current
2 points: Current and
Current
2 points: Pulse volt-
age and Pulse volt-
age/current
2 points: Current and
Current
2 points: Pulse volt-
age and Pulse volt-
age/current
2 points: Current and
Current
4 points: Pulse volt-
age and Pulse volt-
age/current and
Current (2 points)
2 points: Pulse volt-
age and Pulse volt-
age/current
2 points: Current and
Current
Relay output
(1 open, 1 closed)
Relay output
(1 open, 1 closed)
and 1 current (trans-
fer) output
Outputs (control/
transfer)
4
2
(See note
3.)
4
2
(See note
3.)
2
(See note
3.)
4
Auxiliary
outputs
(SUB)
Optional functions
2
6
2
4
4
No
inputs
Event
No
RS-485
RS-485
No
RS-485
nications
commu-
Serial
E5ER-Q4B
E5ER-C4B
E5ER-Q43B-FLK
(See note 2.)
E5ER-C43B-FLK
(See note 2.)
E5ER-QT3DB-FLK
(See note 2.)
E5EAR-CT3DB-
FLK (See note 2.)
E5ER-QC43B-FLK
E5ER-QT3DW-FLK
E5ER-CT3DW-FLK
E5ER-PRTDF
E5ER-PRQ43F-FLK
Model
E5ER
2