E5ER-PRQ43F-FLK AC100-240 Omron, E5ER-PRQ43F-FLK AC100-240 Datasheet - Page 6

no-image

E5ER-PRQ43F-FLK AC100-240

Manufacturer Part Number
E5ER-PRQ43F-FLK AC100-240
Description
CONTROLLER DIGITAL 100-240V
Manufacturer
Omron
Series
E5ERr
Type
Digital Controllerr
Datasheet

Specifications of E5ER-PRQ43F-FLK AC100-240

Input Type
Current, Voltage, RTD, Thermocouple (Multiple)
Controller Type
Proportional (PID)
Temperature Range
Selectable, Varies By Input Type
Output Type
Relay + Voltage/Current
Supply Voltage
100 ~ 240VAC
Size
48mm W x 96mm H (1/8 DIN)
Communications
RS-485 (CompoWay/F)
Display Type
LCD; 5 Digit (2), 3 Digit
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Features
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
E5ER-PRQ43F-FLKAC100-240
E5ERPRQ43FFLKAC100240
■ Communications Specifications
DeviceNet
Transmission path connection
Communications method
Synchronization method
Baud rate
Transmission code
Data bit length
Stop bit length
Error detection
Flow control
Interface
Retry function
Communications buffer
Communications response send wait time 0 to 99 ms, Default: 20 ms
Communications protocol
Communications
functions
Connection format
Baud rate
Communications media
Communications distance
Supply voltage
Allowable voltage range
Current consumption
Maximum number of nodes that can be
connected
Maximum number of slaves that can be
connected
Error control
Power supply
Item
Remote I/O
communications
I/O allocations
Message
communications
Multiple points
RS-485 (two-wire, half duplex)
Start-stop synchronization
9,600, 19,200, or 384,000 bps
ASCII
7 or 8 bits
1 or 2 bits
Vertical parity (none, even, odd)
Block check character (BCC): CompoWay/F
CRC-16: Modbus
None
RS-485
None
217 bytes
Conforms to DeviceNet
• Master-slave connections (polling, bit-strobe, COS, or cyclic)
• Conform to DeviceNet specifications.
• Can allocate any I/O data from the Configurator.
• Can allocate any data, such as parameters specific to the Devicenet, and the Digital Controller
• Up to 2 blocks for the IN Area, up to a total of 100 words.
• One block for the OUT Area, up to 100 words (first word is always allocated to Output Enable
• Explicit message communications
• CompoWay/F communications commands can be sent (commands are sent in explicit mes-
Combination of multidrop and T-branch connections (for trunk and drop lines)
DeviceNet: 500, 250, or 125 kbps, or automatic detection of master baud rate
Special 5-wire cable (2 signal lines, 2 power lines, and 1 shield line)
Baud rate
500 kbps
250 kbps
125 kbps
The values in parentheses apply when Thin Cables are used.
DeviceNet power supply: 24 VDC
DeviceNet power supply: 11 to 25 VDC
50 mA max. (24 VDC)
64 (includes Configurator when used)
63
CRC error detection
Power supplied from DeviceNet communications connector.
variable area.
Bits).
sage format).
Network length
100 m max. (100 m max.)
250 m max. (100 m max.)
500 m max. (100 m max.)
Specifications
Drop line length
6 m max.
6 m max.
6 m max.
Total drop line length
39 m max.
78 m max.
156 m max.
E5ER
6