H7AN-RT8-AC100-240 Omron, H7AN-RT8-AC100-240 Datasheet - Page 10

no-image

H7AN-RT8-AC100-240

Manufacturer Part Number
H7AN-RT8-AC100-240
Description
COUNTER DIGITAL LED 100-240V
Manufacturer
Omron
Datasheet

Specifications of H7AN-RT8-AC100-240

Count Rate
*
Number Of Digits/alpha
*
Input Type
*
Output Type
*
Voltage - Supply
*
Display Type
*
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
H7ANRT8AC100240
H7AN-2D, -2DM
H7AN-E2D, -E2DM
Arrangement and Functions of Specification Selection Switches
Nomenclature
■ Nomenclature
Preset Counter
Note: These settings are the defaults for the specification selection switches.
H7AN-2D
SW2: (A) Operating mode selector
SW4-1: Output phase selector for
SW4-2: Manual reset selector
SW4-3: UP/DOWN selector
H7AN-2DM
SW2: (A) Operating mode selector
SW3: Power failure memory backup
SW4-1: Output phase selector for
SW4-2: Manual reset selector
SW4-3: UP/DOWN selector
transistor output section
transistor output section
(Counting speed: 30 Hz only)
L→H (at count-out)
(See note.)
H→L (at count-out)
Manual reset possible
(See note.)
Manual reset not possible
Up counting (incrementing)
(See note.)
Down counting
(decrementing)
(Counting speed: 30 Hz only)
Memory backup
(See note.)
No memory backup
L→H (at count-out)
(See note.)
H→L (at count-out)
Manual reset possible
(See note.)
Manual reset not possible
Up counting (incrementing)
(See note.)
Down counting
(decrementing)
SW3
1
SW2
SW2
1
1
SW4
SW4
2
2
Seven-segment LED digital display
Indicator lights at count-out
Indicator lights when reset input is received
Pushbutton switch for manual reset
Internal Unit mounting screw
One-shot timer adjuster
Front cover
3
3
H7AN-E2D
H7AN-E2DM
SW1: (A) Counting function selector
SW2: (A) Operating mode selector
SW4-1: Output phase selector for
SW4-2: Manual reset selector
SW1: (A) Counting function selector
SW2: (A) Operating mode selector
SW3: Power failure memory backup
SW4-1: Output phase selector for
SW4-2: Manual reset selector
transistor output section
transistor output section
(Counting speed: 30 Hz only)
L→H (at count-out)
(See note.)
H→L (at count-out)
Manual reset possible
(See note.)
Manual reset not possible
Memory backup
(See note.)
No memory backup
L→H (at count-out)
(See note.)
H→L (at count-out)
Manual reset possible
(See note.)
Manual reset not possible
(Counting speed: 30 Hz only)
SW3
1
SW1 SW2
SW1 SW2
SW4
SW4
1
1
2
2
H7AN-4D, -4DM
H7AN-E4D, -E4DM
Arrangement and Functions of Specification Selection Switches
H7AN-4D
H7AN-4DM
SW2: (A) Operating mode selector
SW3-1: CP1 maximum counting
SW3-2: CP2 maximum counting
SW4-1: Output phase selector for
SW4-2: Manual reset selector
SW4-3: UP/DOWN selector
SW2: (A) Operating mode selector
SW3-1: CP1 maximum counting
SW3-2: CP2 maximum counting
SW3-3: SW3-3: Power failure
SW4-1: Output phase selector for
SW4-2: Manual reset selector
SW4-3: UP/DOWN selector
speed selector
speed selector
transistor output section
speed selector
speed selector
memory backup
transistor output section
30 Hz (See note.)
5 kHz
30 Hz (See note.)
5 kHz
L→H (at count-out)
(See note.)
H→L (at count-out)
Manual reset possible
(See note.)
Manual reset not possible
Up counting (incrementing)
(See note.)
Down counting
(decrementing)
30 Hz (See note.)
5 kHz
30 Hz (See note.)
5 kHz
Memory backup (See note.)
No memory backup
L→H (at count-out) (See note.)
H→L (at count-out)
Manual reset possible
(See note.)
Manual reset not possible
Up counting (incrementing)
(See note.)
Down counting (decrementing)
SW3
1
1
SW3
2
2
3
SW2
SW2
1
1
SW4
SW4
2
2
Indicator lights at count-out
Indicator lights when reset input is received
Pushbutton switch for manual reset
Internal Unit mounting screw
One-shot timer adjuster
Front cover
Seven-segment LED digital display
3
3
H7AN-E4D
SW1: (A) Counting function selector
SW2: (A) Operating mode selector
SW3-1: CP1 maximum counting
SW3-2: CP2 maximum counting
SW4-1: Output phase selector for
SW4-2: Manual reset selector
H7AN-E4DM
SW1: (A) Counting function selector
SW2: (A) Operating mode selector
SW3-1: CP1 maximum counting
SW3-2: CP2 maximum counting
SW3-3: Power failure memory backup
SW4-1: Output phase selector for
SW4-2: Manual reset selector
speed selector
speed selector
transistor output section
speed selector
speed selector
transistor output section
30 Hz (See note.)
5 kHz
30 Hz (See note.)
5 kHz
L→H (at count-out)
(See note.)
H→L (at count-out)
Manual reset possible
(See note.)
Manual reset not possible
30 Hz (See note.)
5 kHz
30 Hz (See note.)
5 kHz
Memory backup
(See note.)
No memory backup
L→H (at count-out)
(See note.)
H→L (at count-out)
Manual reset possible
(See note.)
Manual reset not possible
SW3
1
1
SW3
2
2
3
SW1 SW2
SW1 SW2
H7AN
SW4
SW4
1
1
2
2
10