H7AN-RT8-AC100-240 Omron, H7AN-RT8-AC100-240 Datasheet - Page 16

no-image

H7AN-RT8-AC100-240

Manufacturer Part Number
H7AN-RT8-AC100-240
Description
COUNTER DIGITAL LED 100-240V
Manufacturer
Omron
Datasheet

Specifications of H7AN-RT8-AC100-240

Count Rate
*
Number Of Digits/alpha
*
Input Type
*
Output Type
*
Voltage - Supply
*
Display Type
*
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
H7ANRT8AC100240
Solid-state Outputs (One-stage Counters)
Load Operation when Transistor is ON
External power supply for Load
External power supply for load
8
1
8
1
1-stage counter
(typical)
External
power
supply
9
2
External
power
supply
9
2
Sensor
3
+12 V
10
3
10
+12 V
4
11
4
11
1.5 KΩ
1.5 ΚW
5
12
5
12
Load
Load
Load
6
Load
13
13
6
7
14
7
14
Power supply
for load
*
Power supply
for load
( + )
30 VDC max.
( − )
*This diode is necessary if the supply voltage is below 12 V.
Note: 1. The total current consumption of the sensor and load
Vout =
Load Operation when Transistor is OFF
The output voltage (V out)
is calculated as follows:
2. The capacity of the load must not exceed the switching
3. The polarities of the power supply terminals are not
1.5 (kΩ) + RL
8
1
must not exceed the capacity of the external power
supply (80 mA).
capacity of the transistor (100 mA).
reversible. Check connections before applying voltage to
the power supply terminals to avoid damaging the Counter.
12 RL
External
power
supply
9
2
3
+12 V
10
(V)
4
11
1.5 KΩ
Connected to the input
terminals of other equipment
5
12
Load
V out
6
13
Load
7
14
Power supply
for load
(= RL)
H7AN
16