104479-9 TE Connectivity, 104479-9 Datasheet - Page 3

SHORT POINT CONT 15 DPLX STMPD LF

104479-9

Manufacturer Part Number
104479-9
Description
SHORT POINT CONT 15 DPLX STMPD LF
Manufacturer
TE Connectivity
Datasheets

Specifications of 104479-9

Rohs Compliant
YES
Product Type
Contact
Termination Method To Wire/cable
Crimp
Wire Insulation Diameter (mm [in])
0.64 – 1.52 [0.025 – 0.060]
Connector Series
Short Point
With Insulation Support
Yes
Applied Pressure
Standard
Contact - Rated Current (a)
3
Voltage Rating (vac)
300
Termination Resistance (m?)
12
Insulation Resistance (m?)
5,000
Dielectric Withstanding Voltage (v)
750
Crimp Area Plating
Bright Tin
Wire Range (mm [awg])
0.20-0.60² [24-20]
Contact Type
Socket
Contact Plating, Mating Area, Material
Gold (15)
Contact Base Material
Copper Alloy C7025
Rohs/elv Compliance
RoHS compliant, ELV compliant
Lead Free Solder Processes
Not relevant for lead free process
Rohs/elv Compliance History
Always was RoHS compliant
Approved Standards
UL E28476, CSA LR7189
Operating Temperature (°c)
-65 – +105
Applies To
Wire/Cable
Packaging Method
Strip

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
104479-9
Manufacturer:
TE
Quantity:
49 538
3.6.
4.
4.1.
4.2.
4.3.
4.4.
Rev B
Product Qualification and Requalification Test Sequence
QUALITY ASSURANCE PROVISIONS
Qualification Testing
A.
B.
Requalification Testing
If changes significantly affecting form, fit or function are made to the product or manufacturing process,
product assurance shall coordinate requalification testing, consisting of all or part of the original testing
sequence as determined by development/product, quality and reliability engineering.
Acceptance
Acceptance is based on verification that the product meets the requirements of Figure 1. Failures
attributed to equipment, test setup or operator deficiencies shall not disqualify the product. When
product failure occurs, corrective action shall be taken and samples resubmitted for qualification.
Testing to confirm corrective action is required before resubmittal.
Quality Conformance Inspection
The applicable quality inspection plan will specify the sampling acceptable quality level to be used.
Dimensional and functional requirements shall be in accordance with the applicable product drawing
and this specification.
NOTE
Sample Selection
Samples shall be prepared in accordance with applicable Instruction Sheets and shall be selected
at random from current production. Test group shall consist of a minimum of 5 connectors of
maximum position size available containing at least 30 contacts total with receptacles crimped to
wire and an equal amount of posts of identical plating type and thickness to mate with receptacles.
All contacts shall be crimped to appropriate size tin plated stranded copper test conductors in
accordance with Application Specification 114-25038.
Test Sequence
Qualification inspection shall be verified by testing samples as specified in Figure 2.
(a) See paragraph 4.1.A.
(b) Numbers indicate sequence in which tests are performed.
(c)
(d) Precondition samples by mating and unmating for 10 cycles.
Energize at 18° C temperature rise current level for 100% loading.
Examination of product
Termination resistance
Temperature rise vs current
Vibration
Temperature life
Mixed flowing gas
Test or Examination
Figure 2
Test Sequence (b)
Test Group (a)
6(c)
4(d)
1,9
2,7
3,8
1
5
108-1472-1
3 of 6

Related parts for 104479-9