104483-8 TE Connectivity, 104483-8 Datasheet

64 SHORT PT RCPT HSG DR .100CL

104483-8

Manufacturer Part Number
104483-8
Description
64 SHORT PT RCPT HSG DR .100CL
Manufacturer
TE Connectivity
Series
Short Point Seriesr
Datasheets

Specifications of 104483-8

Rohs Compliant
YES
Product Type
Receptacles / Sockets - Housings
Contact Gender
Socket (Female)
Pitch
2.54 mm
Number Of Positions / Contacts
64
Number Of Rows
2
Row Spacing
2.54 mm
Mounting Style
Wire
Termination Style
Crimp
Housing Material
Thermoplastic, Glass Filled
Voltage Rating
300 VAC
Current Rating
3 A
Operating Temperature Range
- 65 C to + 105 C
Connector Type
Housing
Termination Method To Wire/cable
Crimp
Mating Connector Lock
Without
Connector Series
Short Point
Keyed
No
Flame Retardant
Yes
Housing Configuration
Both Ends Closed
Contact - Rated Current (a)
3
Voltage Rating (vac)
300
Termination Resistance (m?)
12
Insulation Resistance (m?)
5,000
Dielectric Withstanding Voltage (v)
750
Centerline (mm [in])
2.54 [0.100]
Row-to-row Spacing (mm [in])
2.54 [0.100]
Number Of Positions
64
Contact Type
Socket
Connector Style
Receptacle
Mating Alignment
With
Mating Alignment Type
Polarizing Tab
Housing Color
Black
Ul Flammability Rating
UL 94V-0
Rohs/elv Compliance
RoHS compliant, ELV compliant
Lead Free Solder Processes
Not relevant for lead free process
Rohs/elv Compliance History
Always was RoHS compliant
Approved Standards
UL E28476, CSA LR7189
Operating Temperature (°c)
-65 – +105
Lead Free Status / Rohs Status
 Details

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
104483-8
Manufacturer:
TE Connectivity AMP Connectors
Quantity:
145
1.
1.1.
1.2.
2.
2.1.
3.
3.1.
3.2.
3.3.
©2011 Tyco Electronics Corporation,
a TE Connectivity Ltd. Company
All Rights Reserved
TE logo is a trademark.
SCOPE
Content
This specification covers performance, tests and quality requirements for TE Connectivity (TE) short
point receptacle contact and connector system. This contact is a separable electrical connection device
for mating to .025 inch square posts. It can be crimped to 20 to 32 AWG wire sizes and is intended to
be used with a connector housing with centerline spacing of at least .100 inch.
Qualification
When tests are performed on subject product line, procedures specified in 109 Series Test
Specifications shall be used. All inspections shall be performed using applicable inspection plan and
product drawing.
APPLICABLE DOCUMENTS
The following documents form a part of this specification to the extent specified herein. Unless
otherwise specified, latest edition of the document applies. In the event of conflict between
requirements of this specification and product drawing, product drawing shall take precedence. In the
event of conflict between requirements of this specification and referenced documents, this specification
shall take precedence.
TE Documents
!
!
!
!
REQUIREMENTS
Design and Construction
Product shall be of design, construction and physical dimensions specified on applicable product
drawing.
Materials
!
!
Ratings
!
!
!
109-1: General Requirements for Test Specifications
109 Series: Test Specifications as indicated in Figure 1
114-25038: Application Specification
501-292: Qualification Test Report
Contact: Copper alloy, duplex plated gold and tin over nickel plating
Housing: Polyamide, black, glass filled, UL94V-0
Voltage: 300 volts AC
Current: Signal application only
Temperature: -65 to 105° C
| Indicates change
*Trademark
Product
Specification
Connector, Short Point Receptacle Contact
For latest revision, visit our website at www.te.com/documents.
For Regional Customer Service, visit our website at www.te.com
Other products, logos, and company names might be trademarks of their respective owners.
108-1472
11Mar11 Rev A
1 of 6
LOC B

Related parts for 104483-8

104483-8 Summary of contents

Page 1

... SCOPE 1.1. Content This specification covers performance, tests and quality requirements for TE Connectivity (TE) short point receptacle contact and connector system. This contact is a separable electrical connection device for mating to .025 inch square posts. It can be crimped AWG wire sizes and is intended to be used with a connector housing with centerline spacing of at least .100 inch. ...

Page 2

Performance and Test Description Product is designed to meet electrical, mechanical and environmental performance requirements specified in Figure 1. Unless otherwise specified, all tests shall be performed at ambient environmental conditions per Test Specification 109-1. 3.5. Test Requirements and ...

Page 3

Test Description Mating force. Unmating force. Thermal shock. Humidity-temperature cycling. Temperature life. Mixed flowing gas. Shall meet visual requirements, show no physical damage and shall meet requirements of NOTE additional tests as specified in Test Sequence in Figure 2. Rev ...

Page 4

Product Qualification and Requalification Test Sequence Test or Examination Examination of product Termination resistance Insulation resistance Dielectric withstanding voltage Vibration Physical shock Durability Contact retention Mating force Unmating force Thermal shock Humidity-temperature cycling Temperature life Mixed flowing gas (a) ...

Page 5

QUALITY ASSURANCE PROVISIONS 4.1. Qualification Testing A. Sample Selection Samples shall be prepared in accordance with applicable Instruction Sheets and shall be selected at random from current production. All test groups shall each consist of a minimum of 5 ...

Page 6

Rev A Figure 3 Termination Resistance Measurement Points Figure 4 Vibration & Physical Shock Mounting Fixture 108-1472 ...