IP82C54Z Intersil, IP82C54Z Datasheet - Page 15

IC INTERVAL TIMER 5V 8MHZ 24DIP

IP82C54Z

Manufacturer Part Number
IP82C54Z
Description
IC INTERVAL TIMER 5V 8MHZ 24DIP
Manufacturer
Intersil
Type
Programmable Timerr
Datasheet

Specifications of IP82C54Z

Frequency
8MHz
Voltage - Supply
4.5 V ~ 5.5 V
Current - Supply
10mA
Operating Temperature
-40°C ~ 85°C
Package / Case
24-DIP (0.600", 15.24mm)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Count
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
IP82C54Z
Manufacturer:
Intersil
Quantity:
235
Part Number:
IP82C54Z
Manufacturer:
INTERS
Quantity:
1 069
Counter will be loaded with new count on the next CLK pulse
and counting will continue from there.
Operation Common To All Modes
Programming
When a Control Word is written to a Counter, all Control
Logic, is immediately reset and OUT goes to a known initial
state; no CLK pulses are required for this.
Gate
The GATE input is always sampled on the rising edge of
CLK. In Modes 0, 2, 3 and 4 the GATE input is level
sensitive, and logic level is sampled on the rising edge of
CLK. In modes 1, 2, 3 and 5 the GATE input is rising-edge
sensitive. In these Modes, a rising edge of Gate (trigger)
sets an edge-sensitive flip-flop in the Counter. This flip-flop is
then sampled on the next rising edge of CLK. The flip-flop is
reset immediately after it is sampled. In this way, a trigger will
be detected no matter when it occurs - a high logic level
does not have to be maintained until the next rising edge of
CLK. Note that in Modes 2 and 3, the GATE input is both
edge-and level-sensitive.
GATE
GATE
GATE
OUT
OUT
OUT
CLK
CLK
CLK
WR
WR
WR
CW = 1A LSB = 3
CW = 1A LSB = 3
CW = 1A LSB = 3
N
N
N
N
N
N
N
N
N
FIGURE 14. MODE 5
N
N
N
N
N
N
LSB = 5
0
3
N
0
3
15
0
2
0
3
0
2
0
1
0
1
0
2
0
0
0
3
0
0
FF
FF
FF
FF
0
2
FF
FE
0
3
0
1
0
0
0
5
FF
FF
0
4
82C54
Counter
New counts are loaded and Counters are decremented on
the falling edge of CLK.
The largest possible initial count is 0; this is equivalent to 2
for binary counting and 10
The counter does not stop when it reaches zero. In Modes 0,
1, 4, and 5 the Counter “wraps around” to the highest count,
either FFFF hex for binary counting or 9999 for BCD
counting, and continues counting. Modes 2 and 3 are
periodic; the Counter reloads itself with the initial count and
continues counting from there.
NOTE: 0 is equivalent to 2
counting.
STATUS
SIGNAL
MODES
FIGURE 16. MINIMUM AND MAXIMUM INITIAL COUNTS
0
1
2
3
4
5
FIGURE 15. GATE PIN OPERATIONS SUMMARY
MODE
0
1
2
3
4
5
Disables Counting
1) Disables
counting
2) Sets output
immediately high
1) Disables
counting
2) Sets output
immediately high
1) Disables
Counting
GOING LOW
LOW OR
-
-
MIN COUNT
16
4
1) Initiates
Counting
2) Resets output
after next clock
Initiates Counting Enables Counting
Initiates Counting Enables Counting
Initiates Counting
for binary counting and 10
for BCD counting.
1
1
2
2
1
1
RISING
-
-
Enables Counting
Enables Counting
MAX COUNT
HIGH
0
0
0
0
0
0
4
-
-
for BCD
16