DS1615 Maxim Integrated Products, DS1615 Datasheet - Page 18

IC RECORDER TEMP 5V 16-DIP

DS1615

Manufacturer Part Number
DS1615
Description
IC RECORDER TEMP 5V 16-DIP
Manufacturer
Maxim Integrated Products
Type
Temperature Recorderr
Datasheet

Specifications of DS1615

Memory Size
32B
Time Format
HH:MM:SS (12/24 hr)
Date Format
YY-MM-DD-dd
Interface
3-Wire Serial
Voltage - Supply
4 V ~ 5.5 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Through Hole
Package / Case
16-DIP (0.300", 7.62mm)
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DS1615S
Manufacturer:
MAXIM/美信
Quantity:
20 000
CRC HARDWARE DESCRIPTION AND POLYNOMIAL Figure 4
Communication Reset (Asynchronous Mode)
When transmitting the command, parameters, or data to the DS1615, it is possible that communication
might be interrupted. For example, the user might accidentally disconnect the cable linking the device to
the host computer.
asynchronous mode, the DS1615 will reset the communication if it senses a problem.
accomplished via two methods. First, if during the transmission of a byte of data to the DS1615, the stop
bit is not received, communication will be reset. The lack of a valid stop bit indicates that that particular
byte of data was not received correctly. Second, if more then 10-bit times expire between the reception of
one byte of data and the reception of the next required byte, then communication will be reset.
Automatic resetting of communication is not required when communicating in the synchronous mode.
This is because of the function of the
DS1615.
DS1615 COMMANDS
All communication with the DS1615 is accomplished by writing a command to the device followed by
parameter byte/s if required. Table 3 illustrates the commands sup-ported by the DS1615.
DS1615 COMMANDS Table 3
The DS1615 commands are summarized below. Note that if an invalid command is issued, no action is
taken by the device.
COMMAND FUNCTION DESCRIPTION
A5h
22h
33h
44h
55h
Specification
Temperature
Write Byte
Read Page
Memory
Clear
Read
Test
To insure that communication always starts at a known state when in the
Write one byte to RTC, Control registers, and User NV RAM
Read Page
Poll status of temperature extremes
Instructs DS1615 to immediately measure the temperature and store the
result in the Current Temperature register when MIP = 0.
This command clears the datalog, histogram, Temperature Alarm,
Current Samples, Start Time Stamp, Start Delay, and Sample Rate
registers when the Clear Enable bit (CLR) in the Control register is set
to a one.
RST
pin. Pulling
18 of 24
RST
low resets the serial communication of the
This is

Related parts for DS1615