Page 1
... All inspections shall be performed using the applicable inspection plan and product drawing. 1.3. Qualification Test Results Successful qualification testing on the subject product line was completed on 19May89. The Qualification Test Report number for this testing is 501-91. This documentation is on file at and available from Engineering Practices and Standards (EPS). 2. APPLICABLE DOCUMENTS The following documents form a part of this specification to the extent specified herein ...
Page 2
... Materials Materials used in the construction of this product shall be as specified on the applicable product drawing. 3.3. Ratings ! Current, per pin: 1.5 amperes alternating current maximum at 25° C derated to 0.2 amperes maximum at 70° C ambient ! Derating Curve: ! Voltage: 150 volts AC maximum ! Temperature: -40 to 85° C ...
Page 3
... EIA-364-70, Method 1. Subject mated plug and jack to temperature rise at rated current. TE Spec 109-51, Condition B, Method 2. Subject mated plug and jack to 500 cycles at 125% of rated current for 15 minutes ON and 15 minutes OFF. TE Spec 109-90. Measure radiated response from unshielded mated jack and plug ...
Page 4
... Measure force required to unmate plug and jack with latch depressed. EIA-364-98. Apply axial load of 20 pounds to plug housing at a rate of .5 inch per minute with plug mated in jack and latch engaged. Load cable in mated plug with a 17 pound pull in axial direction, rotate plug housing 45 degrees from cable axis, remove load ...
Page 5
... Surge Vibration Durability Mating force Unmating force Plug retention in jack Pull Jack retention to PCB Thermal shock High humidity/temperature cycling (a) See paragraph 4.1.A. NOTE (b) Numbers indicate sequence in which tests are performed. Rev G Test Group ( Test Sequence ( 2,4 2,4 4,6 2 Figure 2 108-1163 2,6 2 ...
Page 6
QUALITY ASSURANCE PROVISIONS 4.1. Qualification Testing A. Sample Selection Modular plug and jack test samples shall be selected at random from current production lots. They shall be prepared for testing in accordance with current Application Specifications and Instruction Sheets. ...
Page 7
Millivolt drop (resistance) due to the 6 inch wire length shall be subtracted from all readings. NOTE Rev G Figure 3 Termination Resistance Measurement Points Figure 4 Plug and Jack Retention Forces 108-1163 ...