6-1658012-1 TE Connectivity, 6-1658012-1 Datasheet
6-1658012-1
Specifications of 6-1658012-1
Available stocks
Related parts for 6-1658012-1
6-1658012-1 Summary of contents
Page 1
... All inspections shall be performed using the applicable inspection plan and product drawing. 1.3. Qualification Test Results Successful qualification testing on the subject product line was completed on 15Oct05. The Qualification Test Report number for this testing is 501-616. This documentation is on file at and available from Engineering Practices and Standards (EPS). 2. APPLICABLE DOCUMENTS The following documents form a part of this specification to the extent specified herein ...
Page 2
... EIA-364-21. Test between adjacent signal contacts, and between all signal contacts and ground of mated specimens. EIA-364-20, Condition I. 675 volts AC at sea level. Test between adjacent signal contacts, and between all signal contacts and ground of mated specimens. EIA-638. Subject contacts to solderability. EIA-364-28, Test Condition V. ...
Page 3
... EIA-364-32, Test Condition III. Subject specimens to 5 cycles between -65 and 125 ° C. EIA-364-31, Method III. Subject specimens to 10 cycles (10 days) between 25 and 65° 100% RH. EIA-364-17, Method A, Test Condition 4. Subject specimens to 105 °for 300 hours ...
Page 4
... Requalification Testing If changes significantly affecting form, fit or function are made to the product or manufacturing process, product assurance shall coordinate requalification testing, consisting of all or part of the original testing sequence as determined by development/product, quality and reliability engineering. Rev B Test Group ( Test Sequence ( ( Figure 2 108-2139 4 ...
Page 5
Acceptance Acceptance is based on verification that the product meets the requirements of Figure 1. Failures attributed to equipment, test setup or operator deficiencies shall not disqualify the product. If product failure occurs, corrective action shall be taken and ...