6-1877846-4 TE Connectivity, 6-1877846-4 Datasheet
6-1877846-4
Specifications of 6-1877846-4
Related parts for 6-1877846-4
6-1877846-4 Summary of contents
Page 1
... Qualification Test Results Successful qualification testing on the subject product line was com pleted on 16Apr07. The Qualification Test Report num ber for this testing is 501-655. This docum entation is on file at and available from Engineering Practices and Standards (EPS). 2. APPLICABLE DOCUM ENTS The following docum ents form a part of this specification to the extent specified herein ...
Page 2
... See Figure 4. EIA-364-21. 500 volts DC inute hold. Test between adjacent contacts. EIA-364-20, Condition I. 1500 volts AC at sea level for 5, 6 and 7 position specim ens; 1200 volts AC at sea level for 10 position specim ens. Test between adjacent contacts ...
Page 3
... EIA-364-32. Subject m ated specim ens to 5 cycles between -50 and 170°C. EIA-364-31, Method III. Subject m ated specim ens to 10 cycles (10 days) between 25 and 65° 100% RH. EIA-364-17, Method A, Test Condition 4, Test Tim e Condition C. Subject m ated specim ens to 105°C for 500 hours ...
Page 4
... Numbers indicate sequence in which tests are performed. (d) Precondition specimens with 10 durability cycles. Rev B Requirem ent See Note. Figure 2 (end) Test Group ( Test Sequence ( 3,7 2,4 2 3(d) 3( Figure 3 108-2249 Procedure EIA-364-65, Class IIA (4 gas). Subject m ated specim ens to environm ental Class IIA for 20 days 2,6 3 ...
Page 5
QUALITY ASSURANCE PROVISIONS 4.1. Qualification Testing A. Specim en Selection Specim ens shall be prepared in accordance with applicable Instruction Sheets and shall be selected at random from current production. Each test group shall consist inim ...