6450128-2 TE Connectivity, 6450128-2 Datasheet - Page 3

MBXL R/A HDR STR 2P+24S+2P

6450128-2

Manufacturer Part Number
6450128-2
Description
MBXL R/A HDR STR 2P+24S+2P
Manufacturer
TE Connectivity
Datasheets

Specifications of 6450128-2

Product Series
XL
Connector Type
Header
Mount Angle
Right Angle
Termination Style
Solder
Mating Type
Squeeze-to-Release
Pcb Mount Retention
With
Guides
With
Voltage Rating (signal) (vac)
60
Voltage Rating (power) (vdc)
200
Termination Post Length (mm [in])
3.43 [0.135]
Sequencing
No
Pcb Mount Retention Type
Retention Clip/Post
Connector Configuration Orientation
Left-to-Right
Centerline, Dc Module (mm [in])
6.35 [0.250]
Centerline, Matrix (mm [in])
2.54 x 2.54 [.100 x .100]
Contact Type
Pin
Contact Material (power)
High Conductivity Copper
Contact Material (signal)
Copper Alloy
Contact Plating, Mating Area, Material
Gold (30)
Connector Style
Plug
Housing Material
High Temperature Thermoplastic
Total Number Of Dc Power
4
Total Number Of Signal
24
Connector Contact Configuration (no. Of Pos./type)
2/DC Power, 24/Signal, 2/DC Power
Rohs/elv Compliance
RoHS compliant, ELV compliant
Lead Free Solder Processes
Wave solder capable to 240°C, Wave solder capable to 260°C, Wave solder capable to 265°C
Rohs/elv Compliance History
Always was RoHS compliant
Application Use
Cable-to-Board
3.5.
Rev C
Initial examination of product.
Final examination of product.
Low level contact resistance, signal
and power contacts.
Contact resistance at rated current,
power contacts.
Insulation resistance.
Withstanding voltage.
Temperature rise vs current.
Vibration, random.
Test Requirements and Procedures Summary
Test Description
Meets requirements of product
drawing.
Meets visual requirements.
Power contacts:
10 milliohms maximum initial.
20 milliohms maximum final.
Signal contacts:
15 milliohms maximum initial.
20 milliohms maximum final.
0.7 milliohm maximum, end of life.
500 megohms minimum for signal
contacts.
1000 megohms minimum for power
contacts.
1 minute hold with no breakdown or
flashover.
30° C maximum temperatur e rise at
specified current.
No discontinuities of 1 microsecond
or longer duration.
See Note.
Figure 3 (continued)
MECHANICAL
ELECTRICAL
Requirement
EIA-364-18.
Visual and dimensional (C of C)
inspection per product drawing.
Document gold plating thickness at
contact interfaces.
EIA-364-18.
Visual inspection.
EIA-364-23.
Subject specimens to 100
milliamperes maximum and 20
millivolts maximum open circuit
voltage.
EIA-364-6.
47 amperes for .300 centerline.
35 amperes for .250 centerline.
See Figure 2.
EIA-364-21.
500 volts DC, 2 minute hold.
Test between adjacent contacts of
mated specimens.
EIA-364-20, Condition I.
1000 volts DC at sea level for
signal contacts.
2500 volts DC for power contacts.
Test between adjacent contacts of
mated specimens.
EIA-364-70, Method 1.
Stabilize at a single current level
until 3 readings at 5 minute
intervals are within 1° C. Test with
single energized contact and with
all adjacent power contacts
energized.
EIA-364-28, Test Condition VII,
Condition E.
Subject mated specimens to 4.90
G's rms between 20-500 Hz.
Fifteen minutes in each of 3
mutually perpendicular planes.
Procedure
108-1973
3 of 7

Related parts for 6450128-2