RD4247MAG3110 Freescale Semiconductor, RD4247MAG3110 Datasheet - Page 13

no-image

RD4247MAG3110

Manufacturer Part Number
RD4247MAG3110
Description
DEV KIT MAG3110 LFSTBUSB
Manufacturer
Freescale Semiconductor
Series
-r
Datasheets

Specifications of RD4247MAG3110

Sensor Type
Accelerometer, 3 Axis
Sensing Range
±10g
Interface
I²C
Sensitivity
1mg/bit
Voltage - Supply
1.95 V ~ 3.6 V
Embedded
No
Utilized Ic / Part
MAG3110
Features
LFSTBUSB For Communication To PC, MAG3110FC & MMA8451Q For System Calibration
Peak Reflow Compatible (260 C)
Yes
Rohs Compliant
Yes
Application Sub Type
Magnetic Sensor
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
RD4247MAG3110
Manufacturer:
FSL
Quantity:
18
Freescale Semiconductor
Low-Pass Filters
HAL
HAL
Sampling Rate
Screen frame
Magnetometer
Accelerometer
Calibration
Settings
1
1
Reset
and Gain
and Gain
RD4247MAG3110 Sensor Toolbox Tilt-Compensated eCompass Kit User’s Guide, Rev. 2
Aligns the magnetometer package to the x, y,
and z axes of the evaluation board in multiples
of 90 degrees. Permitted values are -1, 0, and
1. The magnetometer reading used by the
eCompass algorithms is obtained by
multiplying the raw magnetometer
measurement by this three-by-three matrix.
Aligns the accelerometer package to the x, y,
and z axes of the evaluation board in multiples
of 90 degrees. Permitted values are -1, 0, and
1. The accelerometer reading used by the
eCompass algorithms is obtained by
multiplying the raw magnetometer
measurement by this three-by-three matrix.
The Angles LPF (samples) list-box field sets the 1/e time constant (in samples) of the single-pole,
exponential low-pass filters acting on the roll, pitch, and compass heading angles.
The default setting is 16 samples which equates to 0.4s 1/e convergence at the default, 40-Hz sampling
frequency.
Selects the magnetometer’s output data rates and over-sampling ratios.
The default rate is 40 Hz. For more details on these settings, see the MAG3110 3-Axis, Digital
Magnetometer Data Sheet (MAG3110).
Enables configuration of four parameters used for magnetic calibration.
Resets the Configuration screen settings to default values.
Calibration Interval
Max Equations
Min Equations
Smart FIFO
Configures the data structure that calibrates the device by storing measurements
of the geomagnetic field at different orientations.
The default setting is 3x Pitch times 6x Roll times 6x Yaw ranges to give a total of
108 entries. The alternative setting is 4x Pitch times 8x Roll times 8x Yaw values
for a total of 256 entries.
Selects whether the calibration algorithms execute every 10, 20, 40, 80, 120, or
160 samples.
At the default sampling rate of 40 Hz, this corresponds to a calibration every 0.25,
0.5, 1, 2, 3, or 4 seconds.
Defines the minimum number of measurements stored in the Smart FIFO to be
used for calibration.
The default setting is 16 measurements with the alternatives of 10, 12, and 14.
The lowest setting is 10 because it is impossible for the 10-element calibration
model to be solved when fewer than 10 measurement equations are available.
Defines the maximum number of measurements stored in the Smart FIFO to be
used for calibration.
The default setting is 64, but this can be set as high as 256. Generally, more
measurements are better, but at the expense of increased processing and power
consumption.
If this field is set to 128, 192 or 256, the Smart FIFO field should be set to its larger
value because the smaller value contains only 108 entries which limits
measurements to that number.
Table 1 Configuration Frame
Description
These Hardware Abstraction Layer settings should be
changed only if the sensor toolbox software is being
used with a customer evaluation board whose sensor
package orientation does not match that of the
MAG3110 and MMA8451Q daughter board.
Advanced eCompass Features
13

Related parts for RD4247MAG3110