X9269TV24 Intersil, X9269TV24 Datasheet - Page 9

IC XDCP DUAL 256TAP 100K 24TSSOP

X9269TV24

Manufacturer Part Number
X9269TV24
Description
IC XDCP DUAL 256TAP 100K 24TSSOP
Manufacturer
Intersil
Series
XDCP™r
Datasheet

Specifications of X9269TV24

Taps
256
Resistance (ohms)
100K
Number Of Circuits
2
Temperature Coefficient
300 ppm/°C Typical
Memory Type
Non-Volatile
Interface
I²C, 2-Wire Serial
Voltage - Supply
4.5 V ~ 5.5 V
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
24-TSSOP
Resistance In Ohms
100K
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Table 1. Identification Byte Format
Table 2. Instruction Byte Format
Table 3. Instruction Set
Note: 1/0 = data is one or zero
Read Wiper Counter
Register
Write Wiper Counter Register
Read Data Register
Write Data Register
XFR Data Register to Wiper
Counter Register
XFR Wiper Counter Register
to Data Register
Global XFR Data Registers to
Wiper Counter Registers
Global XFR Wiper Counter
Registers to Data Register
Increment/Decrement Wiper
Counter Register
(MSB)
(MSB)
ID3
I3
0
Instruction
ID2
I2
1
Device Type
Instruction
Identifier
Opcode
9
ID1
I1
0
I3
1
1
1
1
1
1
0
1
0
I2
0
0
0
1
1
1
0
0
0
ID0
I0
1
I1
0
1
1
0
0
1
0
0
1
Instruction Set
I0
1
0
1
0
1
0
1
0
0
RB
A3
RB RA
1/0
1/0
1/0
1/0
1/0
1/0
0
0
0
Selection
X9269
Register
1/0
1/0
1/0
1/0
1/0
1/0
0
0
0
RA
A2
Slave Address
0
0
0
0
0
0
0
0
0
0
1/0 Read the contents of the Wiper Counter
1/0 Write new value to the Wiper Counter
1/0 Read the contents of the Data Register
1/0 Write new value to the Data Register
1/0 Transfer the contents of the Data Register
1/0 Transfer the contents of the Wiper Counter
1/0 Enable Increment/decrement of the Control
P0
0
0
A1
Register pointed to by P0
Register pointed to by P0
pointed to by P0 and RB - RA
pointed to by P0 and RB - RA
pointed to by P0 and RB - RA to its
associated Wiper Counter Register
Register pointed to by P0 to the Data
Register pointed to by RB - RA
Transfer the contents of the Data Registers
pointed to by RB - RA of all four pots to their
respective Wiper Counter Registers
Transfer the contents of both Wiper Counter
Registers to their respective data Registers
pointed to by RB - RA of all four pots
Latch pointed to by P0
0
(WCR Selection)
Pot Selection
(LSB)
(LSB)
P0
A0
Operation
April 17, 2007
FN8173.4

Related parts for X9269TV24