X95840WV20I-2.7 Intersil, X95840WV20I-2.7 Datasheet
X95840WV20I-2.7
Specifications of X95840WV20I-2.7
Related parts for X95840WV20I-2.7
X95840WV20I-2.7 Summary of contents
Page 1
... The DCPs can be used as three-terminal potentiometers or as two-terminal variable resistors in a wide variety of applications including control, parameter adjustments, and signal processing. Ordering Information PART RESISTANCE PART NUMBER MARKING OPTION X95840WV20I-2.7* X95840WV G X95840WV20IZ-2.7* X95840WV Z G (Note) X95840UV20I-2.7* X95840UV G X95840UV20IZ-2.7* X95840UV Z G (Note) *Add “ ...
Page 2
Block Diagram 2 I INTERFACE SDA SCL Pin Descriptions TSSOP PIN SYMBOL 1 RH3 2 RL3 3 RW3 SCL 6 SDA 7 GND 8 RW2 9 RL2 10 RH2 11 RW1 12 RL1 13 ...
Page 3
Absolute Maximum Ratings Storage Temperature . . . . . . . . . . . . . . . . . . . . . . . .-65°C to +150°C Voltage at any Digital Interface Pin with Respect to ...
Page 4
Operating Specifications Over the recommended operating conditions unless otherwise specified. SYMBOL PARAMETER I V Supply Current CC1 CC (Volatile write/read Supply Current CC2 CC (nonvolatile write Current (standby Leakage Current, at LkgDig Pins ...
Page 5
Operating Specifications Over the recommended operating conditions unless otherwise specified. (Continued) SYMBOL PARAMETER t Input Data Setup Time SU:DAT t Input Data Hold Time HD:DAT t STOP Condition Setup Time From SCL rising edge crossing 70 SU:STO t ...
Page 6
WP, A0, A1, and A2 Pin Timing START SCL SDA IN WP, A0, A1 NOTES: 1. Typical values are for T = 25°C and 3.3V supply voltage LSB: [V(RW) - V(RW 255. V(RW) 255 ...
Page 7
Typical Performance Curves 160 85°C CC 140 -40°C CC 120 100 5. -40° 5. 25° ...
Page 8
Typical Performance Curves 0 5. 25°C 0.2 CC 0 85° -40° 132 TAP POSITION (DECIMAL) FIGURE 7. DNL ...
Page 9
Typical Performance Curves Signal at Wiper (Wiper Unloaded) Wiper Movement Mid Point From 80h to 7fh FIGURE 13. MIDSCALE GLITCH, CODE 80h TO 7Fh (WIPER 0) Principles of Operation The X95840 in as integrated circuit incorporating four DCPs with their ...
Page 10
The X95840 is pre-programed with 80h in the four IVRs. TABLE 1. MEMORY MAP ADDRESS NON-VOLATILE 8 — 7 Reserved 6 General Purpose IVR3 2 IVR2 1 IVR1 0 IVR0 WR: Wiper Register, IVR: Initial value Register. ...
Page 11
SCL from Master SDA Output from Transmitter SDA Output from Receiver START FIGURE 16. ACKNOWLEDGE RESPONSE FROM RECEIVER Signals from the Master Signal at SDA Signals from the X95840 Write Operation A Write operation requires a START condition, followed by ...
Page 12
STOP condition) following the last bit of the last Data Byte (See Figure 18). The Data Bytes are from the memory location indicated by an internal pointer. This pointer initial value is determined by the Address Byte in the Read ...
Page 13
... Accordingly, the reader is cautioned to verify that data sheets are current before placing orders. Information furnished by Intersil is believed to be accurate and reliable. However, no responsibility is assumed by Intersil or its subsidiaries for its use; nor for any infringements of patents or other rights of third parties which may result from its use ...